Radio Protocol Timeout
Product Reference Guide
171
Radio Protocol Timeout
This parameter sets the valid wait time before transmission between the handheld reader and
Base Station is considered failed.
When setting this parameter, take into consideration the radio traffic (number of readers in the
same area). The selectable range for this feature is from 02 to 25 seconds.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the number with leading zeroes to yield two digits. For example: 2 = 02, 5 = 05, 25 =
25, etc
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
4. Scan the barcode: SELECT RADIO PROTOCOL TIMEOUT.
5. Scan the appropriate two digits from the keypad in Appendix E, Keypad, that represent
the duration which was determined in the steps above. You will hear a two-beep indica-
tion after the last character.
NOTE
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See Table
20
for some examples of how to set this feature.
Table 20. Wedge Intercode Delay Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
2 Seconds
5 Seconds
10 Seconds
25 Seconds
2
Pad with leading zero(es)
02
05
10
25
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT INTERCODE DELAY SETTING
5
Scan Two Characters From
‘0’ and ‘2’
‘0’ and ‘5’
‘1’ and ‘0’
‘2’ AND ‘5’
6
Scan ENTER/EXIT PROGRAMMING MODE
If you make a mistake before the last character, scan the CANCEL
barcode to abort and not save the entry string. You can then start
again at the beginning.
Summary of Contents for Gryphon I GD4100
Page 14: ...Introduction 12 Gryphon I GD4100 GM4100 NOTES...
Page 34: ...Getting Started 32 Gryphon I GD4100 GM4100 NOTES...
Page 68: ...General Features 66 Gryphon I GD4100 GM4100 NOTES...
Page 80: ...RS 232 ONLY Interface 78 Gryphon I GD4100 GM4100 NOTES...
Page 100: ...RS 232 USB Com Interfaces 98 Gryphon I GD4100 GM4100 NOTES...
Page 118: ...USB OEM Interface 116 Gryphon I GD4100 GM4100 NOTES...
Page 130: ...Wand Emulation Interface 128 Gryphon I GD4100 GM4100 NOTES...
Page 154: ...Data Editing 152 Gryphon I GD4100 GM4100 NOTES...
Page 392: ...LED and Beeper Indications 390 Gryphon I GD4100 GM4100 NOTES...
Page 408: ...Sample Barcodes 406 Gryphon I GD4100 GM4100 NOTES...
Page 410: ...Keypad 408 Gryphon I GD4100 GM4100 6 7 8 9...
Page 411: ...Keypad Product Reference Guide 409 A B C D E F...
Page 412: ...Keypad 410 Gryphon I GD4100 GM4100 NOTES...
Page 422: ...420 Gryphon I GD4100 GM4100 IBM XT Table 60 Scancode Set When Control Character is 00 or 01...
Page 423: ...Product Reference Guide 421 IBM XT cont Table 61 Scancode Set When Control Character is 02...