background image

Scanning Modes

12

Gryphon™ I GD4132

Scanning Modes (continued)

Scan Mode = Flashing

Scan Mode = Always On

Scan Mode = Object Sense

Scan Mode = Trigger Object Sense

 

Summary of Contents for Gryphon I GD4132

Page 1: ...Gryphon I GD4132 General Purpose Corded Handheld Linear Imager Bar Code Reader Quick Reference Guide BSR idware GmbH Jakob Haringer Str 3 A 5020 Salzburg https www bsr at sales bsr at ...

Page 2: ...anual be published you can acquire printed versions by contacting your Datalogic representative Elec tronic versions may either be downloadable from the Datalogic website www datalogic com or provided on appropriate media If you visit our website and would like to make comments or sugges tions about this or other Datalogic publications please let us know via the Contact Datalogic page Disclaimer D...

Page 3: ...ting the Standard Product Defaults 13 RS 232 Interface 14 IBM Interface available with accessory cable 14 USB Interface 15 Keyboard Wedge Interface 16 Country Mode 18 Technical Features 23 LED and Beeper Indications 25 Troubleshooting 26 Ergonomic Recommendations 27 Datalogic Limited Factory Warranty 28 Warranty Coverage 28 Warranty Claims Process 28 Warranty Exclusions 29 No Assignment 29 Risk of...

Page 4: ...2 Gryphon I GD4132 NOTES ...

Page 5: ...ify translate decom pile reverse engineer disassemble or extract the inner workings of the Software ii copy the functionality of the Datalogic Prod ucts iii remove any proprietary notices marks labels or logos from the Datalogic Products iv rent or transfer all or some of the Software to any other party without Datalogic s prior written consent 1 3 Title to the licensed Software shall be and remai...

Page 6: ...oftware will conform substantially to the applicable Datalogic Product docu mentation for the period specified in the same provided that the Soft ware is used with the Datalogic Product Datalogic s entire liability and End User s sole and exclusive remedy for any breach of the foregoing limited warranty will be at Datalogic s option the provision of a down loadable patch or replacement software Da...

Page 7: ... DFARS 252 227 7013 c 1 ii whichever is applicable 8 2 If End User is using the Datalogic Product outside of the United States End User must comply with the applicable local laws of the country in which the Datalogic Product is used and with U S export control laws Without prejudice of the foregoing the End User agrees to not export or re export the Software any part thereof or any process or serv...

Page 8: ...federal courts of the State of Oregon located in either Multnomah or Lane counties shall have exclusive jurisdiction over all matters regard ing this Agreement except that Datalogic shall have the right at its absolute discretion to initiate proceedings in the courts of any other state country or territory in which End User resides or in which any of End User s assets are located In the event an a...

Page 9: ...d arbitrator will be the sole arbitra tor provided that the arbitrator was validly and properly appointed All proceedings will be conducted including all documents presented in such proceedings in the English language The English language ver sion of these terms and conditions prevails over any other language version 11 4 Attorneys Fees In the event an action is brought to enforce the terms and co...

Page 10: ...Software Product Policy 6 Gryphon I GD4132 NOTES ...

Page 11: ...l under dim lighting conditions or noisy environments The Green Spot together with the fast reading and decoding capabilities make the Gryphon I GD4132 readers the best choice to improve productivity in retail and office environments hospitals pharmacies light industrial warehouses and manufacturing plants The Gryphon I GD4132 readers offer multi interface options USB Keyboard Wedge RS 232 and Wan...

Page 12: ...Connect Disconnect Cable 8 Gryphon I GD4132 Connect Disconnect Cable Connect Host Interface Keyboard Wedge Interface 1 2 ...

Page 13: ...Aim and Scan Quick Reference Guide 9 RS 232 Interface USB Interface Aim and Scan 3 012345 012345 ...

Page 14: ...psed Trigger Hold Multiple When the trigger is pulled scanning starts and the product scans until the trigger is released or a programmable duration1 has elapsed Reading a label does not disable scanning Double Read Timeout2 pre vents undesired multiple reads while in this mode Trigger Pulse Multiple When the trigger is pulled and released scanning is activated until programmable dura tion1 has el...

Page 15: ...turned on automatically when an item is placed in reader s field of view If the trigger is pulled the reader acts as if it is in Trigger Single mode Double Read Timeout3 prevents undesired multiple reads while in this mode Trigger Object Sense This mode is similar to Object Sense except that a trigger pull is required to activate the decoder Scan Mode Trigger Single Scan Mode Trigger Hold Multiple...

Page 16: ...Scanning Modes 12 Gryphon I GD4132 Scanning Modes continued Scan Mode Flashing Scan Mode Always On Scan Mode Object Sense Scan Mode Trigger Object Sense ...

Page 17: ... on the back cover of this manual Resetting the Standard Product Defaults If you aren t sure what programming options are in your imager or you ve changed some options and want the fac tory settings restored scan the Factory Default Settings barcode below This will copy the factory configuration for the currently active interface to the current configuration Factory Default Settings Some interface...

Page 18: ...o use an RS 232 interface scan the barcode for the desired RS 232 host type Select RS 232 Standard Select RS 232 Wincor Nixdorf Select RS 232 OPOS for use with OPOS UPOS JavaPOS IBM Interface available with accessory cable Select IBM Port 5B Select IBM Port 9B ...

Page 19: ...When using a USB interface the imager auto detects the USB cable and defaults to the USB keyboard interface Select USB Keyboard with standard key encoding Select USB COM STD1 simulates RS 232 standard interface Select USB Alternate Keyboard with alternate key encoding Select USB OEM Select USB KBD APPLE for Apple computers 1 Download the correct USB Com driver from www data logic com ...

Page 20: ...rd type Select KBD AT AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Standard Key Encoding Select KBD AT NK IBM AT PS2 with standard key encoding but without external kbd Select KBD AT ALT AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Alternate Key Select KBD AT ALT NK for IBM AT PS2 with alternate key encoding but without external keyboard ...

Page 21: ...t KBD XT PC XT w Standard Key Encoding Select KBD IBM 3153 for IBM Terminal 3153 Select KBD IBM M for IBM Terminals 31xx 32xx 34xx 37xx make only keyboard Select KBD IBM MB for IBM Terminals 31xx 32xx 34xx 37xx make break keyboard Select KBD DIG VT for DIGITAL Terminals VT2xx VT3xx VT4xx ...

Page 22: ...70 80 90 95 w Std Key Encoding Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 without Alternate Key Keyboard Wedge for IBM AT PS2 without alter nate key encoding but without external key board All other interfaces support ONLY the following Country Modes U S Belgium Britain France Germany Italy Spain Sweden COUNTRY...

Page 23: ...rence Guide 19 COUNTRY MODE continued Country Mode Belgium Country Mode Britain Country Mode Croatia Country Mode Czech Republic Country Mode Denmark Supports only the interfaces listed in the Country Mode feature description ...

Page 24: ...hon I GD4132 COUNTRY MODE continued Country Mode France Country Mode French Canadian Country Mode Germany Country Mode Hungary Country Mode Italy Supports only the interfaces listed in the Country Mode feature description ...

Page 25: ...nce Guide 21 COUNTRY MODE continued Country Mode Japanese 106 key Country Mode Lithuanian Country Mode Norway Country Mode Poland Country Mode Portugal Supports only the interfaces listed in the Country Mode feature description ...

Page 26: ...yphon I GD4132 COUNTRY MODE continued Country Mode Romania Country Mode Slovakia Country Mode Spain Country Mode Sweden Country Mode Switzerland Supports only the interfaces listed in the Country Mode feature description ...

Page 27: ...put current at 5V 460 mA max 2 5 mA RS 232 sleep mode 2 5 mA USB suspend Input Power 2 42W max in the 5V 5 range Performance Characteristics Light Source Dual LEDs Tilt Roll Tolerance 35 from normal Pitch Yaw Tolerance 65 Skew Tolerance 65 Field of View 10 0 25 4cm wide at 12 5 31 8cm from the reader Depth of Field Typical 3 mil 2 9 to 4 7 7 5cm to 12cm 13 mil 1 2 to 23 6 3cm to 60cm 20 mil 1 2 to...

Page 28: ...6xx ports5B and 9B available with accessory cable USB Com Std USB Keyboard USB Alternate Keyboard USB OEM Keyboard Wedge AT with or w o Alternate Key IBM AT PS2 with or w o Alternate Key PC XT IBM 3153 IBM Termi nals 31xx 32xx 34xx 37xx make only and make break keyboard Digital Terminals VT2x VT3xx VT4xx and Apple and Wand Emulation User Environment Operative Temperature 32 to 131 F 0 to 55 C Stor...

Page 29: ...efer ence the PRG for a more detailed list Indication LED Beeper Power up LED flashes blinks on power up how ever this may be too rapid to view With a USB interface the LED blinks until enu meration with the host is completed Imager beeps four times at highest fre quency and volume upon power up Good Read LED behavior for this indication is configu rable using the PRG One beep at current frequency...

Page 30: ...imager is pro grammed to read the type of barcode scanned Refer to the Product Reference Guide PRG for more information Barcode label is unreadable Check the label to ensure it is not defaced Try scanning another barcode type Distance betweenimager and barcode is incorrect Move imager closer to or further from the barcode Barcode is decoded but not transmitted to the host Imager not pro grammed fo...

Page 31: ...correct heights Reduce or eliminate vibration Reduce or eliminate direct pressure Provide adjustable workstations Provide adequate clearance Provide a suitable working environment Improve work procedures CAUTION In order to avoid or minimize the potential risk of ergonomic injury follow the recom mendations below Consult with your local Health Safety Manager to ensure that you are adhering to your...

Page 32: ...o scrap all parts removed from the repaired prod uct The warranty period shall extend from the date of ship ment from Datalogic for the duration published by Datalogic for the product at the time of purchase Warranty period Datalogic warrants repaired hardware devices against defects in workmanship and materials on the repaired assembly for a 90 day period starting from the date of shipment of the...

Page 33: ...d by faulty operations improper use abuse misuse wear and tear negligence improper storage or use of parts or accessories not approved or supplied by Datalogic iii any claimed defect or damage caused by the use of prod uct with any other instrument equipment or apparatus iv any claimed defect or damage caused by the failure to provide proper maintenance including but not limited to cleaning the up...

Page 34: ... CUSTOMER S SOLE AND EXCLUSIVE REMEDY FOR WARRANTY CLAIMS UNDER NO CIRCUMSTANCES WILL DATALOGIC BE LIABLE TO CUSTOMER OR ANY THIRD PARTY FOR ANY LOST PROFITS OR ANY INCIDENTAL CONSEQUEN TIAL IN DIRECT SPECIAL OR CONTINGENT DAMAGES REGARDLESS OF WHETHER DATALOGIC HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES Risk of Loss Customer shall bear risk of loss or damage for product in transit to D...

Page 35: ... SUPPORT link which gives you access to Downloads by selecting your product model from the dropdown list in the Search by Product field for spe cific Data Sheets Manuals Software Utilities and Drawings Repair Program for On Line Return Material Authori zations RMAs plus Repair Center contact informa tion Customer Service containing details about Mainte nance Agreements Technical Support through em...

Page 36: ...fectants listed below are recommended for use on Datalogic ADC s Disinfectant Ready Enclosures CAUTION Be sure to turn off power and unplug the device from electrical outlet before clean ing Cleaners Disinfectants Formula 409 Glass and sur face cleaner CaviWipes Isopropyl alcohol Clorox bleach Dish soap and water Hepacide Quat II Windex Original Blue Sani Cloth Virex II 256 Disinfectants may be ha...

Page 37: ...cleaning solution Be sure to apply the solution to your cloth first Wring excessive liquid from the cloth 2 Use the cloth to wipe down the surface of the unit Use cotton swabs lightly moistened to reach in corners and crevices 3 Use another clean dry cloth to remove any residue of the cleaning agent and ensure the unit is dry ...

Page 38: ...Cleaning Procedure 34 Gryphon I GD4132 NOTES ...

Page 39: ......

Page 40: ...C August 2018 www datalogic com 2014 2018 Datalogic S p A and or its affiliates All rights reserved Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S A and the E U BSR idware GmbH Jakob Haringer Str 3 A 5020 Salzburg https www bsr at sales bsr at ...