Technical Specifications
Quick Reference Guide
33
Item
Description
Depth of Field (Typical)
a
3 mil – 2.9” to 4.7” (7.5cm to 12cm)
13 mil
d
– 1.2” to 23.6” (3cm to 60cm)
20 mil – 1.2” to 31.5” (3cm to 80cm)
Minimum Element Width
3 mil
Print Contrast Minimum
15% minimum reflectance
Decode Capability
UPC/EAN/JAN, P2 /P5 add-ons; Code 39; Italian Pharma-
code 39; Code 128; C128 ISBT; Code 128 add-ons; I 2 of 5;
Standard 2 of 5; Code 11;Codabar; EAN 128; Code 93; MSI;
GS1 DataBar™ Omnidirectional, GS1 DataBar™ Limited,
GS1 DataBar™ Expanded; Code4, Code5.
Interfaces Supported
b
RS-232 Std, RS-232 Wincor-Nixdorf, RS-232 OPOS, IBM
46xx (ports5B and 9B), USB Com Std., USB Keyboard, USB
Alternate Keyboard, USB OEM, Keyboard Wedge (AT with
or w/o Alternate Key, IBM AT PS2 with or w/o Alternate
Key, PC-XT, IBM 3153, IBM Terminals 31xx, 32xx,34xx,
37xx make only and make break keyboard, Digital Termi-
nals VT2x, VT3xx, VT4xx, and Apple) and Wand Emula-
tion.
User Environment
Operating Temperature
32° to 122° F (0° to 50° C)
Charging Temperature
32° to 104° F (0° to 40° C)
Storage Temperature
-4° to 158° F (-20° to 70° C)
Humidity
Operating: 5% to 90% relative humidity,
non-condensing
Drop Specifications
Scanner withstands 18 drops from 1.8 meters
(5.9 feet) to concrete
Ambient Light Immunity
Up to 100,000 Lux
Contaminants Spray/rain
Dust/particulates
IEC 529-IP52 (scanner only)
ESD Level
16 KV
a.
13 mils DOF based on EAN. All others are Code 39. All labels grade A, typical
environmental light, 20°C, label inclination 10°
b. See Interface Selection on page 19 for a listing of available interface sets by
model type.