background image

Regulatory Information

Quick Reference Guide

49

CLUSIVE REMEDY FOR WARRANTY CLAIMS. UNDER NO CIRCUM-
STANCES WILL DATALOGIC BE LIABLE TO CUSTOMER OR ANY 
THIRD PARTY FOR ANY LOST PROFITS, OR ANY INCIDENTAL, 
CONSEQUENTIAL IN-DIRECT, SPECIAL OR CONTINGENT DAMAG-
ES REGARDLESS OF WHETHER DATALOGIC HAD ADVANCE NO-
TICE OF THE POSSIBILITY OF SUCH DAMAGES.

Risk of Loss

Customer shall bear risk of loss or damage for product in transit 
to Datalogic. Datalogic shall assume risk of loss or damage for 
product in Datalogic’s possession. In the absence of specific writ-
ten instructions for the return of product to Customer, Datalogic 
will select the carrier, but Datalogic shall not thereby assume any 
liability in connection with the return shipment.

Summary of Contents for Gryphon I GM4100-BK

Page 1: ...Gryphon I GM410X General Purpose Handheld Linear Imager Barcode Reader with Datalogic s STAR Cordless System Quick Reference Guide...

Page 2: ...www datalogic com or provided on appropriate media If you visit our website and would like to make comments or suggestions about this or other Datalogic publications please let us know via the Contac...

Page 3: ...and Alone Layouts 18 Select the Interface Type 20 Interface Selection 20 Configuring the Interface 20 Keyboard Interface 25 Standard Factory Settings 25 Scancode Tables 25 Country Mode 25 Caps Lock St...

Page 4: ...NOTES...

Page 5: ...l Proprietary Information does not include any information that the receiving party can establish was 1 in the public domain 2 already in the receiving party s possession or rightfully known prior to...

Page 6: ...End User s internal business purposes End User shall take steps to protect the Proprietary Information no less securely than if it were End User s own intellectual prop erty 5 3 The provisions of this...

Page 7: ...PARTY FOR LOST PROFITS LOST DATA INTERRUPTION OF BUSINESS OR SERVICE OR FOR ANY OTHER SPECIAL CONSEQUENTIAL CONTINGENT INDIRECT INCIDENTAL PUNITIVE EXEMPLARY OR OTHER SIMILAR DAMAGES EVEN IF DATALOGI...

Page 8: ...neys Fees In the event an action is brought to enforce the terms and condi tions of this Agreement the prevailing party shall be entitled to reasonable attorneys fees both at trial and on appeal END S...

Page 9: ...Station The base charger station may be configured in desk application to hold the reader in two different positions either a horizontal or standing position in order to provide the most comfortable u...

Page 10: ...elow 2 Using your thumbs push open the plastic tabs on the bottom of the base to free the wing holders A tool such as a rigid pen or a flat screwdriver can be used to change the mounts Do not allow it...

Page 11: ...ation Base Station Connection and Routing Fully insert the Power Ca ble and Interface I F Cable connectors into their respective ports in the underside of the Base Station see Figure 1 Then connect to...

Page 12: ...the power cord can be changed to ac commodate the base station positioning horizontal stand or wall mounting The cables can be looped around to the front of the Base Station or fed directly out the b...

Page 13: ...in Figure 4 on page 9 Keyboard Wedge interface cables have a Y connection where its female end mates with the male end of the cable from the key board and the remaining end at the keyboard port on th...

Page 14: ...or similar object into the hole on the base as shown in Figure 5 Figure 5 Disconnecting the Cable Using the BC40xx Radio Base Base LEDs LEDs on the Gryphon I Base provide information about the Base s...

Page 15: ...more detailed explanation Display The Gryphon I is also available with an optional Display The FSTN Display with white LED backlight provides additional in formation Figure 7 Gryphon I Display LED STA...

Page 16: ...he battery to become hot explode or ignite and cause serious injury Lithium ion battery packs may get hot explode or ignite and cause serious injury if exposed to abusive conditions Be sure to follow...

Page 17: ...s safety and protection devices which if damaged may cause the battery to generate heat explode or ignite CAUTION Do not place the battery in or near fire on stoves or other high temperature locations...

Page 18: ...e batteries separately from the device in comply with European Directive 2006 66 EC 2011 65 EU 2002 96 EC and 2012 19 EU and subsequent modifications US and China regulatory and others laws and regula...

Page 19: ...y 1 With a screwdriver unscrew the battery cover screw 2 Unplug the three screws securing the battery holder and unplug the white connector Before proceeding read Battery Safety on the preceding pages...

Page 20: ...Remove the old battery from its place if present and insert the new battery in the same position 5 Replace the battery holder plug in the connector and return the contacts circuit to its previous loca...

Page 21: ...e it is necessary to link the handheld with the base To link the handheld and the base press the trigger to wake it and place it on the base If the reader was previously linked to another base you mus...

Page 22: ...Layout In stand alone systems each cradle is connected to a single Host Figure 10 Multiple Stand Alone Layouts Many stand alone connections can operate in the same physical area without interference...

Page 23: ...RS 232 OPOS USB IBM 46XX Configuring the Interface Scan the programming barcode which selects the appropriate in terface type matching the system the reader will be connected to Next proceed to the co...

Page 24: ...232 standard interface Select RS232 STD RS 232 Wincor Nixdorf Select RS232 WN RS 232 for use with OPOS UPOS JavaPOS Select RS 232 OPOS USB Com to simulate RS 232 standard interface Select USB COM STD...

Page 25: ...UPOS JavaPOS Select USB OEM a Download the correct USB Com driver from www datalogic com KEYBOARD AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Standard Key Encoding Select KBD AT KeyboardWedgeforIBM...

Page 26: ...AT ALT NK PC XT w Standard Key Encoding Select KBD XT Keyboard Wedge for IBM Terminal 3153 Select KBD IBM 3153 Keyboard Wedge for IBM Terminals 31xx 32xx 34xx 37xx make only keyboard Select KBD IBM M...

Page 27: ...23 KEYBOARD continued USB Keyboard with standard key encoding Select USB Keyboard USB Keyboard with alternate key encoding Select USB Alternate Keyboard USB Keyboard for Apple computers Select USB KBD...

Page 28: ...nterfaces Country Mode This feature specifies the country language supported by the keyboard Only the following interfaces support ALL Country Modes USB Keyboard without alternate key encoding AT PS 2...

Page 29: ...ide 25 COUNTRY MODE ENTER EXIT PROGRAMMING MODE Country Mode U S Country Mode Belgium Country Mode Britain Country Mode Croatia Country Mode Czech Republic Supports only the interfaces listed in the C...

Page 30: ...n I GM410X COUNTRY MODE continued Country Mode Denmark Country Mode France Country Mode French Canadian Country Mode Germany Country Mode Hungary Supports only the interfaces listed in the Country Mod...

Page 31: ...7 COUNTRY MODE continued Country Mode Italy Country Mode Japanese 106 key Country Mode Lithuanian Country Mode Norway Country Mode Poland Country Mode Portugal Supports only the interfaces listed in t...

Page 32: ...phon I GM410X COUNTRY MODE continued Country Mode Romania Country Mode Slovakia Country Mode Spain Country Mode Sweden Country Mode Switzerland Supports only the interfaces listed in the Country Mode...

Page 33: ...rmat in which the reader sends charac ter data This applies to keyboard wedge interfaces This does not apply when an alternate key encoding keyboard is selected ENTER EXIT PROGRAMMING MODE Caps Lock S...

Page 34: ...s the setting of the Numbers Lock Numlock key while in keyboard wedge interface This only applies to alter nate key encoding interfaces It does not apply to USB keyboard ENTER EXIT PROGRAMMING MODE Nu...

Page 35: ...Mode prior to scanning them Scan an ENTER EXIT barcode once to enter Programming Mode scan the desired parameter set tings then scan the ENTER EXIT barcode a second time to ac cept your changes exit P...

Page 36: ...ical charge time for full charge from full discharge 4 hours with 12V external power supply adaptera a Charge Times are much lower when battery is within daily typical operating condition Max 22 hours...

Page 37: ...edge AT with or w o Alternate Key IBM AT PS2 with or w o Alternate Key PC XT IBM 3153 IBM Terminals 31xx 32xx 34xx 37xx make only and make break keyboard Digital Termi nals VT2x VT3xx VT4xx and Apple...

Page 38: ...E Russia Gost Australia Ctick China SRRC Singapore IDA Anatel Brazil 910 MHz model USA Canada FCC IC Mexico NOM Cofetel LED class safety IEC Class 1 Radio Features 433MHz model 910MHz model Working Ce...

Page 39: ...s of powering up Reader beeps four times at highest fre quency and vol ume upon power up Good Read Beep A label has been successfully scanned by the reader LED behavior for this indica tion is configu...

Page 40: ...ThefollowingindicationsONLYoccurwhenthereaderis in Programming Mode Label Program ming Mode Entry A valid program ming label has been scanned LED blinks con tinuously Reader sounds four lowfre quency...

Page 41: ...been successfully programmed via labels and the reader has exited Programming Mode N A Reader sounds one high fre quencybeepand 4 low frequency beeps followed by reset beeps Label Program ming Mode C...

Page 42: ...w LED blinking 1Hz Data labels are transmitted to the HOST Yellow LEDs turned off for 100mSec Programming Mode Yellow LED blinks quickly ConfigurationalignmentwiththeHHisin progress Red LED blinks qui...

Page 43: ...odic cleaning to ensure best per formance during scanning operations Contacts on the scanner and the base should also be cleaned as needed to ensure a good connection Use a soft dry cloth to clean the...

Page 44: ...against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may c...

Page 45: ...power connector of the Base itself Cofetel Mexico Update CAUTION Do not attempt to open or otherwise service any compo nents in the optics cavity Opening or servicing any part of the optics cavity by...

Page 46: ...lements Scanner Lead Pb Mercury Hg Cadmium Cd Hexavalent Chromium Cr VI Polybrominated biphenyls PBB Polybrominated diphenyl ethers PBDE PART Printed Circuit Board Assembly X O O O O O Assy Optics Blo...

Page 47: ...ble of Restricted Elements Base Lead Pb Mercury Hg Cadmium Cd Hexavalent Chromium Cr VI Polybrominated biphenyls PBB Polybrominated diphenyl ethers PBDE PART Printed Circuit Board Assembly X O O O O O...

Page 48: ...a prejudicial mesmo de esta es do mesmo tipo e n o pode causar interfer ncia a sistemas operando em car ter prim rio GM4100 BK D433 BC4030 BK 433 01 07898916345802 0019 10 4727 0019 10 4727 01 0789891...

Page 49: ...net www datalogic com German Informationen zur Entsorgung von Elektro und Elektronik Altger ten WEEE erhalten Sie auf der Webseite www datalogic com Spanish Si desea informaci n acerca de los procedim...

Page 50: ...46 Gryphon I GM410X Imager Labeling Labels are shown here to illustrate their location only Please view the labels on your product for actual details PATENTS PENDING 239045 C US Scanner Regulatory La...

Page 51: ...nty period shall extend from the date of shipment from Datalogic for the duration published by Datalogic for the product at the time of purchase Warranty period Datalogic warrants repaired hard ware d...

Page 52: ...ance with prod uct manual v any defect or damage caused by natural or man made disaster such as but not limited to fire water damage floods other natural disasters vandalism or abusive events that wou...

Page 53: ...S OF WHETHER DATALOGIC HAD ADVANCE NO TICE OF THE POSSIBILITY OF SUCH DAMAGES Risk of Loss Customer shall bear risk of loss or damage for product in transit to Datalogic Datalogic shall assume risk of...

Page 54: ...Regulatory Information 50 Gryphon I GM410X NOTES...

Page 55: ...auf da das Produkt den folgenden Normen entspricht Esta declaraci n se basa en el cumplimiento de los productos con las siguientes normas Datalogic ADC Srl Via S Vitalino 13 Lippo di Calderara di Reno...

Page 56: ...the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S A and the E U Datalogic ADC Inc 959 Terry Street Eugene OR 97402 USA Telephone 1 541 683 5700 Fax 1...

Reviews: