background image

2

Gryphon™ GPS4400

to End User. Title to the Software shall be and remain with Datalogic or the third party
from whom Datalogic has obtained a licensed right. As used in this Agreement, the
term "purchase" or its equivalents when applied to the Software shall mean "acquire
under license." End User is not entitled to receipt or use of the source code to any
Software.

2.2  End User shall not copy, modify, decompile, disassemble, reverse engineer, or other-

wise reproduce or remanufacture the Software, whether modified or unmodified, nor
sell, assign, sublicense, distribute, lend, rent, give, or otherwise transfer the Software
to any other person or organization, for purposes other than as expressly provided in
this Agreement, without Datalogic's prior written consent.

3. Transfers, Support.

3.1 Any copying, installing, reproduction, remanufacture, reverse engineering, electronic

transfer, or other use of the Software on other than the designated Datalogic Product
will be a material breach of this Agreement. However, Datalogic may elect not to ter-
minate this Agreement or the granted licenses, but instead may elect to notify End
User that End User is deemed to have ordered and accepted a license for each breach-
ing use. End User shall pay Datalogic the applicable list price for such licenses as of
the date of such breach.

3.2 End User shall not sell, assign, sublicense, distribute, lend, rent, give, or otherwise

transfer the Datalogic Product to any third party unless such third party agrees with
Datalogic in writing to be bound by the terms and conditions of this Agreement. Any
such transfer of the Datalogic Product absent such agreement shall be null and void.

3.3 End User may obtain support for Software from Datalogic at Datalogic's standard

support fees and under Datalogic's standard support terms and conditions in effect at
the time the support is requested.

4. Intellectual Property.

End User acknowledges that the Software constitutes valuable trade secrets of Datalogic
or Datalogic's third party licensors and that the Software is protected by intellectual prop-
erty laws and treaties. The license set forth in this Agreement does not transfer to End
User any ownership of Datalogic's or its third party licensors' copyrights, patents, trade-
marks, service marks, trade secrets, or other intellectual property rights and End User shall
have no right to commence any legal actions to obtain such rights. End User shall not
remove, modify, or take any other action that would obscure any copyright, trademark, pat-
ent marking, or other intellectual property notices contained in or on the Datalogic Product.

5. Proprietary Information.

5.1 End User acknowledges that Proprietary Information is the confidential, proprietary,

and trade secret property of Datalogic and Datalogic's third party licensors and End
User acquires no right or interest in any Proprietary Information.

5.2 End User shall not disclose, provide, or otherwise make available the Proprietary

Information of Datalogic or its third party licensors to any person other than End
User's authorized employees or agents who are under confidentiality agreement, and
End User shall not use the Proprietary Information other than in conjunction with use
of the Datalogic Product exclusively for End User's internal business purposes. End
User shall take steps to protect the Proprietary Information no less securely than if it
were End User's own intellectual property.

5.3 The provisions of this Proprietary Information Section shall survive and continue for

five (5) years after the termination of this Agreement.

Summary of Contents for Gryphon I GPS4400

Page 1: ...Gryphon I GPS4400 On Counter Presentation Scanner Quick Reference Guide...

Page 2: ...ting your Datalogic representative Electronic versions may either be downloadable from the Datalogic website www datalogic com or provided on appropriate media If you visit our website and would like...

Page 3: ...ting Modes 16 Technical Features 18 Host Interface Connections 23 LED and Beeper Indications 24 Indicators 25 Error Codes 28 GPS4400 Dimensions 29 Ergonomic Recommendations 31 Regulatory Information 3...

Page 4: ...NOTES...

Page 5: ...r in printed online or other form 1 3 Proprietary Information means a source code object code software documenta tion and any related internal design system design data base design algorithms technolo...

Page 6: ...rt for Software from Datalogic at Datalogic s standard support fees and under Datalogic s standard support terms and conditions in effect at the time the support is requested 4 Intellectual Property E...

Page 7: ...Datalogic will defend End User against any claim in a lawsuit that the Datalogic Product furnished hereunder infringe a United States patent or copyright of a third party and Datalogic will pay any d...

Page 8: ...and with the English language version of this Agreement The provisions of the United Nations Convention on International Sale of Goods shall not apply to this Agreement 10 Termination 10 1 Either part...

Page 9: ...he prevailing party shall be entitled to reasonable attor neys fees both at trial and on appeal END Software Product Policy Datalogic reserves the right to ship its products with the latest version of...

Page 10: ...6 Gryphon GPS4400 NOTES...

Page 11: ...s free or handheld scanning and helps reduce accidental misreads of items caused by stray laser scan lines improving productivity and customer satis faction Its aggressive imaging performance and intu...

Page 12: ...gnature capture and document scanning capabilities The GPS4400 supports several modes that can be used as a trigger This module has the ability to automatically sense objects and trig ger itself A con...

Page 13: ...he Reader Scan the appropriate bar code for your reader s interface type from the following section RS 232 Interface RS 232 standard interface Select RS 232 STD RS 232 Wincor Nixdorf Select RS 232 W N...

Page 14: ...red by it No additional power supply is required The reader auto detects the USB and defaults to the USB KBD interface To simulate a Keyboard scan the bar code below Interface Selection USB KBD Select...

Page 15: ...ce Guide 11 To simulate a serial interface scan the bar code below Interface Selection USB COM USB OEM for use with OPOS UPOS JavaPOS Select USB OEM IMPORTANT Download the correct USB COM driver from...

Page 16: ...gn the holes on the bottom of the scanner with the posts on the stand and push down to snap in place To remove just pull straight up to detach the reader from the base For specific size information se...

Page 17: ...with the device using a serial or USB cable and can also create configuration bar codes to print Using Programming Bar Codes This manual contains bar codes which allow you to reconfigure your reader...

Page 18: ...oduct can also be restored to its original factory default set tings Reference the PRG for this option and for a list of standard factory settings Aiming System A number of options for customizing con...

Page 19: ...Spot Duration Successful reading can be signaled by a good read green spot Use the bar codes that follow to specify the duration of the good read pointer beam after a good read ENTER EXIT PROGRAMMING...

Page 20: ...d sent through the host interface manual triggering can be enabled in this read mode through option setting Automatic Always On Scanning is continually on Automatic Object Sense Scanning is turned on...

Page 21: ...Programming Quick Reference Guide 17 Operating Modes continued Serial On Line Automatic Always On Automatic Object Sense CSNRM01 CR CSNRM02 CR CSNRM03 CR...

Page 22: ...tics Color White Gray Dark Gray Black Dimensions Without Stand Height 74 mm Length 95 mm Width 64 mm With Stand Height 121 mm Length 107 mm Width 73 mm Weight Without Stand 295 0 g 10 4 oz With Stand...

Page 23: ...rating peak 300 mA Idle standby typical 55 mA OnLine Serial OnLine Modes 105 mA Automatic Object Sense Mode No idle in Automatic Mode Performance Characteristics Nominal Frame Rate 53 frames second Li...

Page 24: ...417 6 6mil PDF 417 10mil PDF 417 15mil 1 6 0 0 0 0 13 7 22 4 34 6 0 6 0 0 0 0 5 4 8 8 13 6 DataMatrix 10mil DataMatrix 15mil 2 3 0 0 14 5 23 2 0 9 0 0 5 7 9 1 QR Code 10mil QR Code 15mil 2 3 0 0 14 3...

Page 25: ...of decoding the following symbolo gies using multiple frames i e Multi Frame Decoding Datamatrix Inverse Datamatrix Datamatrix is configurable for the following parameters Normal or Inverted Square o...

Page 26: ...to 90 relative humidity non condens ing Drop specifications 5 drops from 4 feet 1 2 m to concrete Ambient Light immunity Up to 100 000 Lux Contaminants IEC529 IP52 ESD Level 16 KV Regulatory LED Emis...

Page 27: ...ent 1 RTS out RS 232 Request to Send output from scanner 2 D USB D PluS 3 D USB D Minus 4 GND Ground 5 RX RS 232 Receive Data input to scanner 6 TX RS 232 Transmit Data output from scanner 7 VCC 5Vdc...

Page 28: ...tton and an indicator LED Trigger But ton Press for manual trigger Green LED ON Good Read or trigger button press Green LED Blinks USB enumeration or interface inactive waiting for change of configura...

Page 29: ...eeper Power up Beep The reader is in the process of power ing up Reader beeps four times at highest frequency and vol ume upon power up Good Read Beep A label has been successfully scanned by the read...

Page 30: ...Green Spota flashes momen tarily Upon successful read of a label the software shall turn the green spot on for the time speci fied by the config ured value N A N A Image Capture On when ready to captu...

Page 31: ...ram ming Mode Accep tance of Partial Label In cases where multi ple labels must be scanned to program one feature this indi cation acknowledges each portion as it is successfully scanned N A Reader so...

Page 32: ...Replaceable Unit isolation mode If the reader is reset the sequence will be repeated Press and release the trigger to hear the FRU indi cation code The following table describes the LED flashes beep c...

Page 33: ...Error Codes Quick Reference Guide 29 GPS4400 Dimensions Figure 1 GPS4400 Without Stand Dimensions in mm...

Page 34: ...Error Codes 30 Gryphon GPS4400 Figure 2 GPS4400 Dimensions With Stand Dimensions in mm...

Page 35: ...orrect heights Reduce or eliminate vibration Reduce or eliminate direct pressure Provide adjustable workstations Provide adequate clearance Provide a suitable working environment Improve work procedur...

Page 36: ...y approved by the part responsible for compliance could void the user s authority to operate the equipment This equipment has been tested and found to comply with the limits for a Class B digital devi...

Page 37: ...l numerique n emet pas de bruits radioelectriques depassant les limites applicables aux appareils numeriques de la classe B prescrites dans le Reglement sur le brouillage radioelec trique edicte par l...

Page 38: ...ng The sample labels shown below are for illustrative purposes only Please view the labels on your product for actual details as they may vary Aiming System The Gryphon aiming system meets the Class 2...

Page 39: ...ET SIEHE BILD LE RAYON LASER EST VISIBLE L OEIL NU ET IL EST MIS PAR LA FEN TRE D SIGN E SUR L ILLUSTRATION DANS LA FIGURE A LUZ L SER ES VISIBLE AL OJO HUMANO Y ES EMITIDA POR LA VENTANA INDI CADA EN...

Page 40: ...VE STANDARD PER LA SICUREZZA LASER Questo prodotto risulta conforme alle normative vigenti sulla sicurezza laser alla data di produzione CDRH 21 CFR 1040 e EN 60825 1 Non si rende mai necessario aprir...

Page 41: ...rstellung den g ltigen EN 60825 1 und CDRH 21 CFR 1040 Normen f r die Lasersicherheit Es ist nicht notwendig das Ger t wegen Betrieb oder Installations und Wartungs Arbeiten zu ffnen Der Produkt benut...

Page 42: ...d ouvrir l appareil pour l installation l utilisa tion ou l entretien Le produit utilise une diode laser Aucun dommage aux yeux humains n a t constat la suite d une exposition au rayon laser Eviter d...

Page 43: ...za un diodo l ser a baja potencia No son notorios da os a los ojos humanos a consecuencia de una exposici n de corta duraci n Eviten de mirar fijo el rayo l ser as como evitar an cualquiera otra fuent...

Page 44: ...ite internet www datalogic com German Informationen zur Entsorgung von Elektro und Elektronik Altger ten WEEE erhalten Sie auf der Webseite www datalogic com Spanish Sideseainformaci nacercadelosproce...

Page 45: ...y other charges for products returned to any other locations Datalogic ADC Datalogic hardware products are warranted against defects in material and workmanship under normal and proper use The liabili...

Page 46: ...repair or replace product without additional charge for parts and labor Customer shall be responsible for packaging and shipping the product to the designated Datalogic service center with shipping ch...

Page 47: ...transfer in violation of this provision shall be valid or binding upon Data logic DATALOGIC S LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EX PRESS OR IMPLIED ORAL OR WRITTEN STATUTORY OR OTHE...

Page 48: ...lity program that allows for both RS 232 and USBCOM communications interfacing The GUI based application provides an easy mechanism for setting scanner configuration as well as configuration bar code...

Page 49: ...Services and Support Quick Reference Guide 45 NOTES...

Page 50: ...Services and Support 46 Gryphon GPS4400 NOTES...

Page 51: ...a s curit des pro duits ber die Ann herung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Vertr glichkeit und Produktsicherheit entsprechen Basado en la aproximaci n de las leyes de...

Page 52: ...d Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S A and the E U Datalogic ADC Inc 959 Terry Street Eugene OR 97402 USA Telephone 1 541...

Reviews: