Enter/Exit Programming Mode
Reading Parameters
104
Gryphon™ I GD44XX
/
GBT4400/GM440X
Aiming Pointer
Enables/disables the aiming pointer for all symbologies.
Aiming Duration Timer
Specifies the frame of time the aiming pointer remains on after decoding a label, when in trigger
single mode.The range for this setting is from 1 to 255 seconds in 1-second increments. See
in “References” for a description of this feature.
Aiming Pointer = Disable
Aiming Pointer = Enable
$CTAAP00(CR)
$CTAAP01(CR)
DEFAULT
Aiming Off After Decoding
Set Aiming Duration Timer
To configure, scan the ENTER/EXIT PROGRAMMING
MODE bar code above, then the bar code at left fol-
lowed by the digits from the Alphanumeric characters
in
representing your desired
character(s). End by scanning the ENTER/EXIT bar code.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start again at
the beginning.
CANCEL
DEFAULT
LSTM00
LSTM
~