References
280
Gryphon™ I GD44XX
/
GBT4400/GM440X
Aiming Duration Time
Specifies the frame of time the aiming pointer remains on after decoding a label, when in trigger
single mode. The range for this setting is from 1 to 255 seconds in 1-second increments.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20
= 020, etc.
3. Go to
and scan the ENTER/EXIT PROGRAMMING MODE bar code to
enter Programming Mode.
4. Scan the bar code: SELECT AIMING DURATION TIME SETTING.
5. Scan the appropriate three digits from the keypad in
, that represent
the duration which was determined in the steps above. You will hear a two-beep indica-
tion after the last character.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming
Mode.
This completes the procedure. See
for some examples of how to set this feature.
Table 41. Aiming Duration Time Setting Examples
If you make a mistake before the last character, scan the CANCEL bar code
to abort and not save the entry string. You can then start again at the
beginning.
STEP
ACTION
EXAMPLES
1
Desired Setting
1 Second
90 Sec. (1.5 min.)
180 Sec. (3 min.) 255 Seconds (4.25 min.)
2
Pad leading zero(es)
001
090
180
255
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT AIMING DURATION TIME SETTING
5
Scan Three Characters From
‘0’, ‘0’ and ‘1’
‘0’, ‘9’ and ‘0’
‘1’, ‘8’ and ‘0’
‘2’, ‘5’ and ‘5’
6
Scan ENTER/EXIT PROGRAMMING MODE
Summary of Contents for Gryphon Series
Page 43: ...Enter Exit Programming Mode Global Interface Features 40 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 57: ...Enter Exit Programming Mode RS 232 USB Com Interfaces 54 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 235: ...232 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 321: ...318 Gryphon I GD44XX GBT4400 GM440X A B C D E F...