RF Features
Product Reference Guide
285
RF Features
Automatic Configuration Update
When this feature is enabled, the base station and reader will keep their configurations
synchronized. If a reader's configuration is altered by reading programming labels, this change is
automatically transferred and updated in a linked base station. Likewise, if the base station's
configuration is changed using Aladdin or by host commands, then the reader's configuration
will automatically be updated if this feature is enabled.
RF Address Stamping
Source Radio Address Delimiter Character
This option specifies the delimiter character to be placed between the label data and radio
address when address stamping is enabled.
Follow these instructions to select the delimiter character:
1. Determine the desired character, then find its hexadecimal equivalent on the
on the inside back cover. A setting of 00 specifies no delimiter character.
2. Go to
and scan the ENTER/EXIT PROGRAMMING MODE bar code to
enter Programming Mode.
3. Scan the bar code: SET SOURCE RADIO ADDRESS DELIMITER CHARACTER.
4. Scan the appropriate two digits from the keypad in
, that represent
the hexadecimal characters which were determined in the steps above. You will hear a two-
beep indication after the last character.
5. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit.
Table 46. Source Radio Address Delimiter Character Setting Examples
This feature only applies if "Source Radio Address Transmission" on
page 243 is enabled.
If you make a mistake before the last character, scan the CANCEL bar code
to abort and not save the entry string. You can then start again at the
beginning.
STEP
ACTION
EXAMPLES
1
Desired Setting
No delimiter
character
, (comma)
- (dash)
/ (slash)
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SET SOURCE RADIO ADDRESS DELIMiTER CHARACTER
4
Scan Two Characters From
‘0’ and ‘0’
‘2’ and ‘C’
‘2’ and ‘D’
‘2’ AND ‘F’
5
Scan ENTER/EXIT PROGRAMMING MODE
Summary of Contents for Gryphon Series
Page 43: ...Enter Exit Programming Mode Global Interface Features 40 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 57: ...Enter Exit Programming Mode RS 232 USB Com Interfaces 54 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 235: ...232 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 321: ...318 Gryphon I GD44XX GBT4400 GM440X A B C D E F...