References
288
Gryphon™ I GD44XX
/
GBT4400/GM440X
Motion Features
Motionless Timeout
This setting specifies the amount of time that the reader takes to assume that it is in a motionless
condition. The range for this setting is from 500 msec to 25.5 seconds, in 100 millisecond
increments.
Follow these instructions to set this feature.
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0.5 = 0005 = 00, 5 =
050, 20 = 200, etc.
3. Go to
and scan the ENTER/EXIT PROGRAMMING MODE bar code to
enter Programming Mode.
4. Scan the bar code: SELECT MOTIONLESS TIMEOUT SETTING.
5. Scan the appropriate three digits from the keypad in
representing
the duration which was determined in the steps above. You will hear a two-beep indica-
tion after the last character.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming
Mode.
This completes the procedure. See
for examples of how to set this feature.
Table 49. Motionless Timeout Setting Examples
If you make a mistake before the last character, scan the CANCEL bar code
to abort and not save the entry string. You can then start again at the
beginning.
STEP
ACTION
EXAMPLES
1
Desired Setting
500ms
1 sec.
10 sec
9,900ms (9.9 sec.)
2
Divide by 100 (and pad with
leading zeroes to yield two
digits)
005
010
100
250
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT MOTIONLESS TIMEOUT SETTING
5
Scan Two Characters From
‘0’, ‘0’ and ‘5’
‘0’, ‘1’ and ‘0’
‘1’, ‘0’, and ‘0’
‘2’, ‘5’, and ‘0’
6
Scan ENTER/EXIT PROGRAMMING MODE
Summary of Contents for Gryphon Series
Page 43: ...Enter Exit Programming Mode Global Interface Features 40 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 57: ...Enter Exit Programming Mode RS 232 USB Com Interfaces 54 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 235: ...232 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 321: ...318 Gryphon I GD44XX GBT4400 GM440X A B C D E F...