Default Configuration
Quick Reference Guide
15
DATA FORMAT – Concatenation
Concatenation disabled, 2 EAN/UPC codes concatenated, Set First Concatenated Code Length 000 =
any length, Set Second Concatenated Code Length 000 = any length, Set Third Concatenated Code
Length 000 = any length, Set Fourth Concatenated Code Length 000 = any length, Concatenation
with Intercode Delay disabled, Concatenation Timeout 10 seconds, Concatenation Failure Transmis-
sion = Tx codes causing failure, Transmission after Timeout = No code transmission, Concatenation
Result Code ID = No code Identifier
ADVANCED FORMATTING PARAMETERS
format disabled
POWER SAVE
Illumination power = ON
CODE SELECTION
issue identical codes = enable
enabled codes
Standard Code 39: no check digit control, variable code length;
EAN 8/EAN 13 / UPC A/UPC E without ADD ON: UPCE expansion disabled
Interleaved 2/5: check digit control and transmission, variable code length
Code 128: variable code length
PDF417
Datamatrix: rectangular, normal and inverted, variable code length
QR
disabled codes
Code 32, Codabar, Code 93, EAN 128, RSS, Micro PDF417, Postal Codes, Maxicode, Composite Codes
,
Aztec.
READING PARAMETERS
trigger type normal, trigger level mode, flash on = 2 sec, flash off = 2 sec, beeper tone = tone 1,
beeper volume = high, beeper duration = 50 ms, user defined beeper = tone 1, user defined
beeper volume = high, user defined beeper duration = 100 ms, code per scan = one code per scan,
read per cycle = one read per cycle, scan timeout = 5 sec, central code transmission enabled, order
by code length disabled, order by code symbology disabled, autoscan mode disabled, autoscan aim-
ing system enabled, autoscan hardware trigger enabled, autoscan illumination system disabled,
stand autoscan mode = normal, aiming system delay = disabled, good read spot = short, safety
time = 500 ms
IMAGE FORMATTING
Image Preset 1, 2, 3, 4
image format = JPEG, set JPEG quality factor = 50, brightness = 0%, contrast = 0%, zoom =
100%, color depth = 256 gray level.