DEFAULT VALUES
RS232 DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking,
delay disabled, rx timeout 5 sec., ack/nack disabled, FIFO
enabled, serial trigger lock disabled;
DATA FORMAT
: code identifier disabled, no field adjustment,
code length not transmitted,
no header
,
terminator = CR-LF
,
character replacement disabled
IBM DEFAULT SETTINGS
DATA FORMAT
: IBM Standard, code identifier disabled,
no
header
,
no terminator
POWER SAVE
scan rate max, standby disabled, sleep disabled
READING PARAMETERS
hardware trigger, trigger active level, no trigger timeout,
Flash On = 1 sec, Flash Off = .6 sec, one read per cycle,
safety time .5 sec, beeper intensity high, tone 2, beeper type
monotone, beeper length short, good read spot duration
medium, stand recognition beep enabled; automatic
operation aiming light enabled
DECODING PARAMETERS
ink spread enabled, overflow control enabled, interdigit
control enabled, Puzzle Solver™ disabled, decoding safety =
one read
CODE SELECTION
Enabled codes
•
EAN 8/EAN 13 / UPC A/UPC E without ADD ON
check digit transmitted, no conversions
•
Interleaved 2/5
check digit control and transmission, variable length
code; 4-99 characters
•
Standard Code 39
no check digit control, variable length code; 1-99
characters
•
Code 128
variable length code; 1-99 characters
Disabled codes
EAN 128, ISBT128, Code 93, Codabar, pharmaceutical
codes, MSI, Plessey, Telepen, Delta IBM, Code
11,
Code 16K, Code 49, RSS Codes
ADVANCED FORMATTING PARAMETERS*
concatenation disabled, no advanced formats defined
* The advanced formatting parameters may not be compatible
with the IBM 46xx cash register parameters.