background image

1

 DH60 

   

 

66 

4.9.2 

Installing DFU on the Host PC 

 
Datalogic Firmware Utility (DFU) provides administrators with a field upgrade 
mechanism. You must have Microsoft® ActiveSync (for Windows XP devices) or 
Windows Mobile® Device Center (for Windows 7 and Vista devices) already loaded 
and running on the host PC to use DFU. Refer to par. 4.7.1  for  more information 
about Windows Mobile® Device Center. 
 

 

Prior to installing, you must remove any previous versions of DFU 
installed on the host PC. 

NOTE 

 
To install the Datalogic Firmware Utility, complete the following steps on the PC: 
 
1. 

Go to the Datalogic website and download the most current version of   the 
Datalogic Firmware Utility. Unzip the file, then double-click to run 

DFU_Setup. 

exe

 

2. 

Click OK to continue once you have removed previous versions of DFU. 

 
3. 

The Welcome to DFU Setup Program screen opens. 

 

Please exit all Windows applications before running this installer. 

 

Click Next to continue the Setup. 

 

4. 

Follow the onscreen instructions to complete the installation. 

 
 

Summary of Contents for Jet DH60

Page 1: ...ogic and the Datalogic logo are registered trademarks of Datalogic S p A In many countries including the U S A and the E U DH60 Via S Vitalino 13 40012 Lippo di Calderara di Reno Bologna Italy Telephone 39 051 3147011 Fax 39 051 3147561 Datalogic ADC S r l Mobile Computer User s Manual ...

Page 2: ...uld future revisions of this manual be published you can acquire printed versions by contacting your Datalogic representative Electronic versions may either be downloadable from the Datalogic website www datalogic com or provided on appropriate media If you visit our website and would like to make comments or suggestions about this or other Datalogic publications please let us know via the Contact...

Page 3: ...e Computer 15 3 CONNECTIONS 16 3 1 USB Connection 16 3 2 WLAN Connection 18 3 3 WPAN Connections 20 3 4 Wireless and Radio Frequencies Warnings 21 4 USE AND FUNCTIONING 23 4 1 Startup 23 4 1 1 Using the Stylus 24 4 1 2 Touch Gestures 25 4 2 Windows CE Touch Screen Calibration 26 4 3 Data Capture 27 4 3 1 Laser Data Capture 28 4 3 2 Imager Data Capture 29 4 4 Description of the Keyboards 31 4 4 1 R...

Page 4: ...67 4 10 Datalogic Configuration Utility 68 4 11 Datalogic Desktop Utility 69 4 11 1 Administrative Options Admin tab 70 4 11 2 Windows Controls 73 4 12 Autostart 75 4 12 1 Installing CAB Files 75 4 12 2 How AutoStart Uses Wceload 76 4 12 3 Interactive CAB Install 77 4 12 4 Autostart ini 77 5 TECHNICAL FEATURES 83 5 1 Technical Data 83 5 2 Reading Diagrams 86 6 TEST CODES 88 REGULATORY INFORMATION ...

Page 5: ... the SDK Help on Line SERVICES AND SUPPORT Datalogic provides several services as well as technical support through its website Please check our website at www datalogic com under Support Services then Automatic Data Capture and click on the links indicated for further information including Downloads Manuals for the latest versions of user manuals and product guides Software Utilities for the late...

Page 6: ...re Window B Color Display C ON OFF Power Key D Status Light E Front Scan Key F Keyboard G Reset key H Stylus I Laser Safety Label J Loudspeaker K MicroSD Card Slot under battery L Product Label under battery A B C D E F G H I J K L ...

Page 7: ...vii M Right Side Scan Key N Left Side Scan Key O DC Port P Micro USB Port M N P O ...

Page 8: ...1 This page intentionally left blank ...

Page 9: ...or this Error proofing technology is intuitive regardless of how noisy the environment is In quieter retail environments the Green Spot technology prevents unwanted intrusion on the consumer experience by enabling silent scanning The DH60 mobile computer utilizes a Laird Wi Fi IEEE 802 11 bgn radio with fast roaming and PCI compliant encryption levels This powerful combination ensures real time in...

Page 10: ...ll line of mobile computing accessories allow for investment flexibility Single slot docks are available for small stores while four slot docks and multi battery chargers support the largest of warehouses A pistol grip handle easily converts the DH60 mobile computer into a gun form factor suitable for scan intensive receiving and inventories ...

Page 11: ...ic For further details about the DH60 models refer to the web site http www datalogic com For further information regarding Windows CE refer to the website http www microsoft com windowsembedded The currently available models are 941100003 DH60 00N0IM 2N0 CCS0 DH60 Handheld Samsung A8 256MB 512MB bgn Imager Numeric CE6 941100004 DH60 0000LD 2N0 CCS0 DH60 Handheld Samsung A8 256MB 512MB Batch P Las...

Page 12: ...sories necessary for the DH60 connection to the host computer and to the network the cradle one or more connection cables Remove all the components from their packaging check their integrity and compare them with the packing documents Keep the original packaging for use when sending products to the technical assistance center Damage caused by improper packaging is not covered under the warranty CA...

Page 13: ... card slot and insert the card proceed as follows 1 Turn off the DH60 2 Pull the battery latch down and remove the battery pack 3 Insert the microSD card into the slot with the gold contacts facing down 4 Insert the battery s alignment lugs into the recesses then press firmly until the battery latch clicks ...

Page 14: ...proper ESD precautions to avoid damaging the microprocessors in the DH60 or the microSD card itself Proper ESD precautions include but are not limited to working on an ESD mat and ensuring that the operator is properly grounded Do not force the card If you feel resistance remove the card check the orientation and reinsert it Do not use the microSD card slot for any other accessories CAUTION ...

Page 15: ...4ACC0085 DH60 battery 3600 mAh Power Supply 94ACC0087 Direct and single slot dock power supply 94ACC0090 Multi slot dock and battery charger power supply Cables 94A051968 Cable from dock microUSB client to USB Various 94ACC0091 DH60 handle for conversion to pistol grip sold separately 94ACC0092 DH60 holster for belt mounting Use only a Datalogic approved power supply and cables Use of an alternati...

Page 16: ...e a DH60 is to connect the device DC jack to a provided power supply Alternatively the DH60 also be charged by the single slot dock or the four slot dock The battery icon on the Taskbar indicates approximate charge level of the battery and will indicate a low charge when the DH60 needs to be recharged The battery pack autonomy varies according to many factors such as the frequency of barcode scann...

Page 17: ... batteries before first use NOTE Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to the instructions CAUTION Avoid storing batteries for long periods in a state of full charge or very low charge We recommend charging the battery pack every two to three months to keep its charge at a moderate level to maximize battery life CAUTION The DH60 and spare...

Page 18: ...el may display incorrectly for several minutes after the DH60 is disconnected from its charger if the charging cycle is not completed NOTE The DH60 may get warm during charging this is normal and does not mean a malfunction NOTE ...

Page 19: ...TERY PACK To correctly replace the battery pack proceed as follows 1 Turn off the DH60 2 Pull the battery latch down and remove the battery pack 3 Insert the new battery s alignment lugs into the recesses then press firmly until the battery latch clicks ...

Page 20: ...warranty may cause product damage and may cause heat an explosion or fire The area in which the units are charged should be clear of debris and combustible materials or chemicals Do not use the battery pack of this terminal to power devices other than this mobile computer Immediately discontinue use of the battery pack if while using charging or storing the battery pack the battery pack emits an u...

Page 21: ... battery pack to liquids Avoid any knocks or excessive vibrations If the device or the battery is dropped especially on a hard surface you should take it to the nearest Authorised Repair Centre for inspection before continuing to use it Do not replace the battery pack when the device is turned on Do not remove or damage the battery pack s label Do not use the battery pack if it is damaged in any p...

Page 22: ...battery is not sufficiently charged the DH60 will not turn on when the ON OFF Power button is pressed In this case either substitute a sufficiently charged battery insert the DH60 into a powered cradle or plug it into a wall charger NOTE To maximize battery life turn off radios when they are not needed NOTE ...

Page 23: ...BATTERIES AND MAINTENANCE 15 2 2 3 CLEANING THE MOBILE COMPUTER Periodically clean the DH60 with a slightly dampened cloth Do not use alcohol corrosive products or solvents ...

Page 24: ...ndard micro USB cable included in the box to directly connect the DH60 to a host computer to transfer data through the USB interface Key A Host computer C DH60 B Std A to Micro B USB 2 0 cable Connection through the cable complies to the USB 2 0 standard NOTE A B C ...

Page 25: ...ter has been turned on insert the DH60 mobile computer into the cradle Key A Host computer C DH60 Single Slot Dock B Std A to Micro B USB 2 0 cable D Power Supply Connection through the cradle complies to USB 2 0 standard NOTE The actual data transfer speed can be appreciably lower than the maximum theoretical speed NOTE B D C A ...

Page 26: ...a network For models using the 802 11 bgn radio you can find information about the applet for radio configuration http www summitdata com SCU htm To launch this utility you can tap the specific icon if it is visible on the taskbar or you can select the menu item Start Summit and tap the SCU icon Key A DH60 B Access point C Host Application Server A B C A ...

Page 27: ...epending on the radio power mode and security protocol selected it may take up to 30 seconds for the 802 11 bgn radio driver to re associate the radio to the network NOTE Area coverage and radio performance may vary due to environmental conditions access point types or interference caused by other devices microwave ovens radio transmitters etc NOTE In case of heavy usage the DH60 may get warm this...

Page 28: ...to have Bluetooth working the module must be enabled through the Bluetooth Manager see par 4 8 2 NOTE Suspending the terminal powers off the Bluetooth radio and drops the piconet Bluetooth connection When the terminal resumes it takes approximately 10 seconds for the Bluetooth radio driver to re initialize the radio NOTE Area coverage and Bluetooth radio performance may vary due to environmental c...

Page 29: ...s to follow the same recommendations provided by Health Industry Manufacturers Associations for mobile phones Persons with pacemakers Should ALWAYS keep this device more than twenty five 25 cm from their pacemaker and or any other medical device Should not carry this device in a breast pocket Should keep the device at the opposite side of the pacemaker and or any other medical device Should turn t...

Page 30: ... equipment in the area over the air bag or in the air bag deployment area If a vehicle s wireless equipment is improperly installed and the air bag inflates serious injury could result WARNING Turn off the device when in any area with a potentially explosive atmosphere Observe restrictions and follow closely any laws regulations warnings and best practices on the use of radio equipment near fuel s...

Page 31: ... is installed use the ON OFF key to turn the mobile computer on and off As soon as the mobile computer is on the Windows CE 6 0 desktop will appear on the screen Wait a few seconds before starting any activity so that the mobile computer completes its startup procedure Desktop Control Panel Use the stylus par 4 1 1 as suggested to select icons and options The mobile computer goes into power off lo...

Page 32: ...tems To recalibrate the touch screen use the Stylus applet see par 4 6 7 Use only original Datalogic styluses supplied with the product itself In harsh applications use of screen protectors should be taken into consideration in order to extend the touch screen operating life To prevent damage to the screen do not use sharp devices or any device other than the Datalogic provided stylus Do not apply...

Page 33: ...u use a finger or stylus to make a short directional movement over a control or object on the screen Most gestures are a single stroke Windows CE supports five kinds of gestures Tap A tap represents the left click of a mouse Double Tap A double tap represents the left double click of a mouse ...

Page 34: ...the very first DH60 startup following a clean boot to restore the Registry to default values the mobile computer startup see par 4 1 is preceded by the touch screen calibration screen The user must calibrate the touch screen see par 4 7 1 Touch Screen Calibration Screen ...

Page 35: ...USE AND FUNCTIONING 27 4 4 3 DATA CAPTURE To capture data tap Start Settings Control Panel double tap Decoding ...

Page 36: ...sing the SCAN key or the pistol trigger The lighted band emitted by the laser must completely cross the barcode as shown in the figure below If the scan has taken place correctly the Good Read LED glows steadily green for a configurable time if enabled the Good Read Beep plays if enabled the GreenSpot projects a green spot onto the bar code image ...

Page 37: ...simply point the DH60 Imager model onto the code and press the SCAN Key or the pistol trigger The DH60 Imager uses an intelligent aiming system pattern similar to those on cameras indicating the field of view which should be positioned over the code Aiming System If the aiming system pattern is centered over the entire symbology as shown in the following figure either wait for the timeout or relea...

Page 38: ...ld of view indicated by the aiming system pattern will be smaller when the DH60 Imager is closer to the code and larger when it is farther from the code Symbologies with smaller bars or elements mil size should be read closer to the unit Symbologies with larger bars or elements mil size should be read farther from the unit See par 5 1 for further details If the scan has taken place correctly the G...

Page 39: ...h two levels of functionality Secondary functions are accessed by pressing the yellow button first and then any key designated as having an alternate symbol All the keys can be reprogrammed for unique actions defined by the application with the exception of the main Scan key the power key and the yellow modifier key ...

Page 40: ...h a Menu list or browse among folder files Yellow modifier toggle key When pressed once before a standard key it enables the character or function printed in yellow above the key When pressed twice it holds the keyboard in the yellow mode for text entry A third press will return the keyboard to the normal mode The ON OFF Power button powers the DH60 ON or OFF It is placed on the lower right side o...

Page 41: ...ation both the Registry and the file system returns to a clean status that conforms to factory default Warm Boot To perform a warm boot press the reset key on the device front see GENERAL VIEW Cold Boot To perform a cold boot press the yellow modifier key and the reset key Clean Boot To perform a clean boot do the following steps 1 Start menu Settings Control Panel 2 Double tap the RestoreFactoryS...

Page 42: ...igger until the bar code is decoded until the scanner times out or until the user releases the Scan key or trigger Green Light changes to green when a good decode is completed and then remains lit until the user releases the Scan key or trigger When charging Green Light is solid green once the charging process has completed full charge Red Light is solid red while charging Blinking Red Blinking re...

Page 43: ...open a status dialog that will let you disconnect the ActiveSync session without physically disconnecting the device from the PC It is the only way to disconnect a Bluetooth ActiveSync connection Battery icon displays the system battery status It indicates that the battery is charging Bluetooth Manager icon displays whether Bluetooth is enabled paired or turned off Double tap this icon to open the...

Page 44: ...1 DH60 36 4 4 6 CONTROL PANEL From the Start menu tap Settings then Control Panel Below is an expanded view of the Control Panel showing all of the applets Windows CE Control Panel ...

Page 45: ...iguration pages and multiple Barcode symbology pages DECODING CONFIGURATION PAGES Select the desired configuration from the options shown in the figure below and the other Decoding Properties figures on the following pages Select General 1D Bar Code or 2D Bar Code then use the menu or tap the left and right arrow keys to navigate the different pages of the Decoding utility The menu options will ch...

Page 46: ...ification Use it to set volume tone duration interval and number of various types of beeps Good Read From the Decoding Properties page tap Configure General Good Read Use it to enable Good Read indications the use of Green Spot the LED or to set the decoding timeout for decoding labels ...

Page 47: ...ap Configure General Formatting Use it to configure prefix suffix and data separator character strings General Options From the Decoding Properties page tap Configure General General Options Select from Label Programming Enable Symbology IDs and Group Separator Replacement ...

Page 48: ...g Properties page tap Configure General Decoding Options Use it to configure the User ID for symbologies Redundancy and Aggressive Decoding if supported by the decoding module Select a symbology to view or change the available properties settings ...

Page 49: ...SE AND FUNCTIONING 41 4 Devices From the Decoding Properties page tap Configure General Devices Use it to enable or disable the keyboard wedge for Barcode scanner and to enable or disable Clipboard mode ...

Page 50: ...s to navigate the different pages of the barcode symbology pages Select Configure 1D Bar Code from the menu to view other configuration options Each barcode symbology opens to its own page as shown in the figure below Refer to the sample symbology control panels for examples of the types of fields and options you can modify ...

Page 51: ...y Defaults Minimum Settings Maximum Settings Save New Settings Revert to Saved Settings The settings are saved when you tap Yes To permanently save these settings you need to save the Registry using the Persistent Registry applet in the Control Panel When open Decoding Properties acts as a simple barcode test tool that provides the Data decoded and the Data Type of the barcode scanned ...

Page 52: ...ific applications From the control panel main window double tap the DL Buttons icon On the DL Buttons tab customize the program hardware buttons to launch your most used applications Under Select a button select the button you want to assign a function to and then select a program from Assign a function ...

Page 53: ...You cannot delete the following buttons Alt 6 Left Button Pistol Trigger Right Button Scan Assign a function This pull down list displays the available functions Application Displays path to the selected application Browse Select tap to browse for application files You can associate an executable program with the specified Button Arguments Type the command line arguments that are needed for the sp...

Page 54: ...tion in the Add Key textbox COMMAND DESCRIPTION Enter Key Enter the desired key combination in this text box to define a Button OK Select tap OK to add the specified Button X Select tap X to cancel adding the specified Button Make sure you do not attempt to add a Button that is already defined NOTE 2 Select tap OK to save the new Button If you select tap X the key will not be saved ...

Page 55: ... using alphanumeric characters Barcodes containing characters associated with assigned Buttons will trigger the action or application assigned to that Button CAUTION Assigning an action to a character used in a password can render the DH60 unusable Please be careful when choosing keys CAUTION ...

Page 56: ...open applications The application switcher is activated via an assigned shortcut key specified in the DL Buttons tab see par 4 6 2 When the assigned button is pressed the dialog shown below will be displayed Press the assigned button to cycle through the running applications when the dialog is open Press Enter to switch to the selected application or Esc to close the application switcher ...

Page 57: ...ONS Wireless networking has a customized control Summit Client Utility SCU specific to the radio There are two methods to access the SCU Start Programs Summit SCU Or From the Control Panel main window double tap Wi Fi to open the Summit Client Utility ...

Page 58: ...n to the Main tab Summit Client Utility 1 To create a new profile tap the Profile tab Information about the wireless network can be entered directly in the profile tab or by pressing Scan when the desired network ESSID is in range ...

Page 59: ...en select the desired SSID 3 Click the Configure button 4 Follow the on screen instructions to setup security parameters for your network For more detailed settings specific to your installation please contact your wireless network administrator ...

Page 60: ... settings Return to the Main tab if you have not previously selected Commit you will be prompted to save your changes At the Main tab select the profile you just created If you used the scan button the desired profile will have the same name as the ESSID ...

Page 61: ...USE AND FUNCTIONING 53 4 Use the Status tab to check connectivity to the network More detailed information about the applet for radio configuration can be found at http www summitdata com SCU htm ...

Page 62: ...empt to select one item with the stylus another item is erroneously selected To recalibrate the touch screen complete the following steps 1 From the Control Panel main window double tap Stylus to open the Stylus Properties applet window 2 Tap Calibration to open the Calibration screen Tap Recalibrate ...

Page 63: ... calibration settings 5 New calibration settings are persistently saved in the Registry Startup Stylus Calibration When starting the terminal a welcome wizard with stylus calibration comes up if valid calibration settings are not available This happens in the following circumstances 1 At the first startup of the terminal 2 After any cold boot if the user skipped stylus calibration earlier 3 After ...

Page 64: ... 2 Volume Sounds From the control panel main window select the Volume Sounds applet by double tapping the Volume Sounds icon The Volume Sounds applet configures audio features of the loudspeaker and appears as follows ...

Page 65: ...gh the following interfaces USB either directly or through the Single Dock Bluetooth see par 4 7 2 To establish a partnership between the DH60 and a host PC start Windows Mobile Device Center and follow the steps below 1 Connect the DH60 to the host PC Windows Mobile Device Center configures itself and then opens 2 On the license agreement screen click Accept 3 On the Windows Mobile Device Center ...

Page 66: ...ooth Manager icon to open the Bluetooth Manager control panel Tap Connections 2 Search for available Bluetooth devices by tapping the button for the type of device you want Printer Serial or All or tap Discovery Discover to skip this step The DH60 will search for Bluetooth devices within range If you attempt to set up a connection when the Bluetooth radio is disabled you will receive a message rem...

Page 67: ...l be displayed in the Discovery tab You can set up a connection to a device in the list by selecting the device and then tapping the Connect button 4 To create a pairing select a service 5 Configure any encryption authentication or virtual port options required by the service selected ...

Page 68: ...ace Device HID Keyboard Serial Personal Area Network PAN Modem Headset Handsfree Virtual Port allows you to specify the incoming port which is used to communicate serially with an incoming device just as if it were a physical COM port This option is available only if you have selected a Printer or Serial service ...

Page 69: ... settings 1 To require Authentication check the checkbox then tap OK 2 If required the Authentication Request dialog will then open requesting that you enter a PIN Use the Input Panel or the keyboard to type the PIN 3 Tap OK to complete The dialog will also appear when an Authentication request is received from another device ...

Page 70: ... you can view the settings by double tapping its name from the Connections tab Tap the arrow to change the Virtual Port or Delete to remove the device pairing Tap Sync to initiate a Sync available only if the service is an ActiveSync connection ...

Page 71: ...luetooth ensure that the two devices are within close range and that both Bluetooth enabled devices are discoverable 1 From the Bluetooth Manager control panel Tap Settings The Settings tab allows you to enable or disable the Bluetooth radio and specify settings for Incoming Connections ...

Page 72: ...select a virtual COM port to use for the connection 5 Tap Find Me if you want to make the DH60 discoverable to other Bluetooth devices for 60 seconds allowing them to set up a connection By default Bluetooth is turned off If you turn it on and then turn off your device Bluetooth also turns off When you turn on your device again Bluetooth turns on automatically NOTE ...

Page 73: ... device downloads If Wavelink Avalanche is not available or you have only a few Datalogic devices to update use the Datalogic Firmware Utility DFU described below to install or update the firmware using an ActiveSync connection The following sections provide procedures for the retrieval and installation of the most current firmware image onto a Datalogic device 4 9 1 Retrieving a Firmware Image Up...

Page 74: ...lling you must remove any previous versions of DFU installed on the host PC NOTE To install the Datalogic Firmware Utility complete the following steps on the PC 1 Go to the Datalogic website and download the most current version of the Datalogic Firmware Utility Unzip the file then double click to run DFU_Setup exe 2 Click OK to continue once you have removed previous versions of DFU 3 The Welcom...

Page 75: ...rams Datalogic DFU Datalogic Firmware Utility 2 Verify that ActiveSync is selected by clicking Communications WMDC ActiveSync 3 Click browse and navigate to the location where you saved the firmware file for your terminal 4 Select the current out file and click Open 5 Click Update 6 DFU will compare the selected firmware image with the firmware already loaded on the device if the image is compatib...

Page 76: ...eSync and then click on the Get from Device icon to receive the device s current configuration Once loaded the Configuration Tree on the left side of the window is used to navigate the device s configuration The right side of the window is a work area where the values of different parameters may be set for each branch of the configuration tree Click on the parameter group branch to open it and ins...

Page 77: ...ations Restrict user access in Internet Explorer Set up configuration and customized error recovery mechanisms Create quick access hot keys and configure trigger actions To open DDU for the first time tap Start Settings Control Panel or Start Programs Device tools and then double tap the icon for Datalogic Desktop Utility You can also open DDU by pressing the appropriate key shortcut The default i...

Page 78: ...y a password when this utility is launched By default the password is 1234 A password can consist of all standard keyboard characters Re Enter Password Carefully re enter the password in the second text box Set Password Select tap Set Password to enable the password To change or remove the password enter a new value re enter the new value and select tap Set Password Set Defaults Select tap Set Def...

Page 79: ...Select tap OK to close the Set Password Confirmation dialog You must select tap Set Password prior to exiting DDU in order to store and activate your new password It is not necessary to select Enable Datalogic Desktop NOTE If you select tap Set Defaults it will remove all custom settings and restore all the factory default settings except a previously set password CAUTION Changing a Password To ch...

Page 80: ...xt time you open the Datalogic Desktop Utility the DDU Password dialog box opens This dialog box will only open if a password was defined 1 Type in your password using either the keypad on the unit or using the stylus on the soft input panel SIP If you enter an incorrect password the system will prompt you to input the correct one 2 Select tap OK to verify the password Or tap X to cancel ...

Page 81: ...ontrols to allow or restrict access to Windows system functions You can disable normal Windows functions such as the taskbar leaving nothing but a blank workspace This allows applications to be run in full screen mode and prevents users from accidental or unauthorized use of the taskbar Internet Explorer and any other resident applications ...

Page 82: ...skbar is checked AutoSIP Enabled Enables the AutoSIP Windows feature Scroll Bars Enabled This control only takes effect in Locked Web Browser When checked displays horizontal and vertical scroll bars to help view large web pages which do not fit the screen When unchecked scroll bars will not be present Windows CE Desktop Enabled Windows CE Desktop Enabled specifies whether the desktop icons are ac...

Page 83: ...g each line with the specified command line arguments It will take into account any AutoStart options at the beginning of the line Upon a Cold Boot AutoStart installs all the CAB files located in the CAB folder If the CAB folder does not exist no CAB files will be installed AutoStart will then run the Autostart ini from the root directory executing each line with the specified command line argumen...

Page 84: ...e CAUTION CAB files are installed by AutoStart using the Wceload exe application The following table shows available command line option Option Description noui Specifies that you will not be prompted for any input during the installation If the CAB file is signed any responses will automatically be answered Yes If the CAB is unsigned then any responses will be answered No silent Suppresses dialog...

Page 85: ...ile should be placed in the AutoStart folder with other CAB files intended for installation on the next reboot 4 12 4 Autostart ini A file named PreAuto ini can also be created in addition to or instead of Autostart ini PreAuto ini is executed before CAB files in the Cab folder are installed Autostart ini is executed after CAB files in the Cab folder are installed The format for the PreAuto ini is...

Page 86: ...omponent of the line in the Autostart ini If the executable path is in a folder that contains spaces in the name quotes are required to distinguish what the actual executable name is The following is an example of this Program Files ScannerApp exe run valid Program Files ScannerApp exe run invalid The second line is an invalid line because there is no way to distinguish the executable from the arg...

Page 87: ...tions elsewhere it is ignored Do not wait on line completion This will cause the line to execute and immediately move onto the next line Query Request user confirmation when running the executable This will halt parsing the Autostart ini until the confirmation is answered This is intended for debugging the Autostart ini file Execute only on Cold Reset Execute only after a warm boot Cold Reset Only...

Page 88: ... current line to complete execution Query Option The query option is intended for use when debugging the autostart ini When a line with this option is executed the following dialog will appear with the specified executable and command line arguments The populated fields shown in the AutoStart Execute Query are described the next table Field Description Line Number This is the line number in the sc...

Page 89: ... used to surround the given field and make it very clear what the value of the field is The following table describes the results of each choice Button Action Yes The current line will execute No The current line will not execute AutoStart will continue parsing the Autostart ini Cancel The current line will not execute and AutoStart will discontinue parsing the Autostart ini ...

Page 90: ...Program with the argument Files App exe Program Files App exe run invalid This will execute Program with the argument Files App exe run Program Files App exe run This will execute the program Program Files App exe with the argument run Windows Pword exe This will confirm the execution of Windows Pword exe If the execution is confirmed AutoStart will immediately process the next line Program Files ...

Page 91: ...ys and two side scan keys OPERATING TEMPERATURE 10 to 50 C 14 to 122 F CHARGING TEMPERATURE 10 to 45 C 50 to 113 F STORAGE TEMPERATURE 20 to 70 C 4 to 158 F HUMIDITY 5 95 non condensing DROP RESISTANCE Withstands 18 drops from 1 5 m 5 0 ft onto a concrete surface PARTICULATE AND WATER SEALING IP54 ELECTROSTATIC DISCHARGE ESD Air 8kV Direct 4kV contact Indirect 8kV coupling Close to the limits of t...

Page 92: ...to 32 GB capacity POWER Single piece rechargeable Li ion Polymer battery pack 2600 mAh at 3 7V 9 6 Watt hours CLOCK Real time clock COMMUNICATIONS WIRED INTERFACES Micro USB WIRELESS LOCAL AREA NETWORKING WLAN Laird IEEE 802 11 b g n WIRELESS PERSONAL AREA NETWORKING WPAN Bluetooth Wireless Technology with EDR IEEE 802 15 v2 1 Use only DL approved battery packs power adapters and charging accessor...

Page 93: ...at 5 mils DEPTH OF FIELD 4 to 40 cm 1 6 to 15 5 in depending on bar code size and density BAR CODES 1 D Codes China Post Code 32 Code 39 Code 93 Code 128 Codabar EAN UPC GS1 DataBar Interleaved 2 5 Matrix 2 5 MSI Standard 25 Trioptic 2D Codes Aztec Code Data Matrix Maxicode Micro QR Code MicroPDF417 PDF417 QR Code GS1 DataBar Composites UPC EAN Composites Postal Codes Australian Post China Post US...

Page 94: ...teed Reading Diagram measured from the device nose 10 skew angle 100 200 300 400 0 200 100 300 400 mm 0 13 mm 5 mils 0 19 mm 7 5 mils 1 4 mm 55 mils 0 25 mm 10 mils 0 33 mm 13 mils 0 50 mm 20 mils 1 00 mm 40 mils 0 100 300 200 400 500 600 700 800 900 mm 0 38 mm 15 mils ...

Page 95: ...d Reading Diagram Measured from the device nose 10 skew angle 50 100 150 200 0 100 50 150 200 mm 0 50 150 100 200 250 300 350 400 450 500 mm 5 0 mil PDF417 6 67 mil PDF417 7 5 mil Code 39 10 mil PDF417 13 mil UPC A 15 mil PDF417 5 0 mil Code 39 20 mil Code 39 ...

Page 96: ...1 DH60 88 6 6 TEST CODES High Density Codes 0 25 mm 10 mils Code 39 17162H 17162 2 5 Interleaved Ë 8NduÌ 0123456784 Code 128 ÌtestwÎ test 80 EAN 13 x 0B2DE5 KKKKLM 80 EAN 8 6450 TRMN ...

Page 97: ...TEST CODES 89 6 Medium Density Codes 0 38 mm 15 mils Code 39 17162H 17162 Interleaved 2 5 Ë 8NduÌ 0123456784 Code 128 ÌtestwÎ test 100 EAN 13 x 0B2DE5 KKKKLM 100 EAN 8 6450 TRMN ...

Page 98: ...1 DH60 90 6 Low Density Codes 0 50 mm 20 mils Code 39 17162H 17162 Interleaved 2 5 Ë 8NduÌ 0123456784 Code 128 ÌtestwÎ test 120 EAN 13 x 0B2DE5 KKKKLM 120 EAN 8 6450 TRMN ...

Page 99: ...TEST CODES 91 6 2D Codes Datamatrix ECC200 Example Inverse Datamatrix ECC200 Example ...

Page 100: ...y tampering will invalidate the warranty When replacing the battery pack or at the end of the operative life of the DH60 mobile computer disposal must be performed in compliance with the laws in force in your jurisdiction Before using the devices and the battery packs read chap 2 Do not submerge the DH60 in liquid products For further information refer to this manual and to the Datalogic web site ...

Page 101: ...SAFETY The laser light is visible to the human eye and is emitted from the window indicated in the figure This information applies to both the DH60 models with laser and Imager Aiming System Laser output window ...

Page 102: ...ly repair item CAUTION Use of controls or adjustments or performance of procedures other than those specified herein may result in exposure to hazardous visible laser light CAUTION The product utilizes a low power laser diode Although staring directly at the laser beam momentarily causes no known biological damage avoid staring at the beam as one would with any very strong light source such as the...

Page 103: ...trum authorities of the specific country in which the installation takes place Be absolutely sure that the system frequencies are correctly set to be compliant with the spectrum requirements of the country The Radio modules used in this product automatically adapt to the frequencies set by the system and do not require any parameter settings ...

Page 104: ...ency tolerance 20 10 6 Spurious emission 36dBm 100kHz 30 1000MHz 33dBm 100kHz 2 4 2 4835GHz 40dBm 1MHz 3 4 3 53GHz 40dBm 1MHz 5 725 5 85GHz 30dBm 1MHz other 1 12 75GHz Existence of an electromagnetic field in the environment may impact device performance and may cause harmful interference to radio communications To reduce that possibility please follow the instructions in the user manual The Minis...

Page 105: ... harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the r...

Page 106: ...ts of laboratory tests toxic or hazardous substance contained in all of the homogeneous materials that the device uses is below the limit requirement in SJ T11363 2006 The table 1 shows the content of toxic or hazardous substance in different part Part Name Toxic or hazardous Substances and Elements Pb Hg Cd Cr VI PBB PBDE PCB Cable Plastic shell Battery Pack Adaptor Single_slot Multi_slot Multi_b...

Page 107: ...isposed of separately from urban waste to avoid potentially negative consequences to the environment and human health and to enable the recovery of materials to obtain a significant savings of energy and resources For more detailed information about disposal contact the supplier that provided you with the product in question or consult the dedicated section at the website http www datalogic com ...

Page 108: ...data in binary form The general format of a barcode symbol consists of a leading margin start character data or message character check character if any stop character and trailing margin Within this framework each recognizable symbology uses its own unique format Baud Rate A measure for data transmission speed Bit Binary digit One bit is the basic unit of binary information Generally eight consec...

Page 109: ...ork card automatically implies Ethernet Defined by the IEEE as the 802 3 standard Ethernet is used to connect computers in a company or home network as well as to connect a single computer to a cable modem or DSL modem for Internet access Firmware Firmware is a software program or set of instructions programmed on a hardware device It provides the necessary instructions for how the device communic...

Page 110: ...es are crosslinked In some cables there are also handshake lines crosslinked In many situations a straight through serial cable is used together with a null modem adapter The adapter contains the necessary crosslinks between the signals One shot key Pressing a one shot key actives the state The state remains active until any other key is pressed If you hold down a one shot state key and you press ...

Page 111: ...easily connected to a computer A plug and play interface it allows a device to be added without an adapter card and without rebooting the computer the latter is known as hot plugging The USB standard developed by several major computer and telecommunications companies supports data transfer speeds up to 12 megabits per second multiple data streams and up to 127 peripherals WLAN A Wireless Local Ar...

Page 112: ...ogic Configuration Utility 68 Datalogic Desktop Utility 69 Datalogic Firmware Utility 65 Description of the Keyboards 31 DH60 Description 1 DL Buttons 44 G General View vi Glossary 100 L Laser Safety 93 LED Class 94 LED Status 34 M MicroSD Card Insertion 5 P Package Contents 4 Power Supply 92 R Radio Compliance 95 Reading Diagrams 86 References v Regulatory Information 92 Replacing the Batteries 1...

Page 113: ...105 V Volume Sounds 56 W Windows CE Touch Screen Calibration 26 Windows Mobile Device Center 57 Wireless and Radio Frequencies Warnings 21 Wireless Communications 49 ...

Page 114: ...ogic and the Datalogic logo are registered trademarks of Datalogic S p A In many countries including the U S A and the E U DH60 Via S Vitalino 13 40012 Lippo di Calderara di Reno Bologna Italy Telephone 39 051 3147011 Fax 39 051 3147561 Datalogic ADC S r l Mobile Computer User s Manual ...

Reviews: