JOYA CRADLE DISPENSER
71
5
The opening at the top of the cabinet must be covered with a grill or mesh,
which allows air to flow freely but protects against access to the inside of the
cabinet. In this way the power supplies can not be reached externally.
Power Supplies
•
Single 300 W power supply capable of supplying all 8 Cradle Dispensers
(91ACC1000 Power Supply 12V 300W).
The power supplies must be mounted inside the cabinet onto their shelves so
that the necessary air flow for cooling the JOYA Cradle Dispensers below is not
limited. In addition, the openings on the power supplies must not be obstructed
at any time, which could impede correct cooling.
If the power supplies are mounted using angular brackets, use the threaded
holes provided on the power supply case. Make sure that the mounting screws
are size M4 and do not penetrate the power supply case by more than 5.5 mm.
5.3.6 AC Power Cabling
Connection of the Power Supply to the AC line must be made using a cable
having characteristics that meet the Safety Normatives currently in force.
The cable must have an earth ground wire that is connected to the earth
ground terminal of the power supply.
The cable must have wire dimensions that meet or exceed the nominal current
and power specifications of the power supply to which it is connected.
There must be a cable clamp applied to the power cable where it enters the
cabinet, which meets the Safety Normatives currently in force.