5.3.8 Cable to Power Supply Connection
All 12 Vdc power supply connections, both the main power cable and the power
junction cables must be made according to the following requirements:
Power Junction Cable
Wires
Connection
Designation
Brown
+12V
+V
Blue
ground
-V
Yellow-Green
earth ground
FG or
5.3.9 Affixing Cables to Cabinet
The ends of the junction cables that are connected to the main cable groups
must be affixed to the cabinet sides so as to guarantee the following conditions:
•
it must be possible to extract the JOYA Cradle Dispenser from the front
of the cabinet while the cable is connected so that the connector can be
plugged in or out of the Cradle Dispenser from outside the cabinet.
•
when the JOYA Cradle Dispenser is mounted in the cabinet, its cable
must be laid against the supporting crosspiece so that it does not block
objects which may accidentally fall through the Cradle Dispenser into the
inside of the cabinet.
Next image shows an example of affixing the Cradle Dispenser cables to the
cabinet. The Cradle Dispenser cables are connected to the main power cables
through IDC connectors.