ZONE SETTING CONFIGURATION AND SELECTION
INSTRUCTION MANUAL
55
•
Define the input combinations.
•
Make sure that the system, which generates the input combination, can dynami-
cally switch the state of the inputs within the required time and without passing
through intermediate invalid combination states.
It is possible to insert a delay up to 100 ms for the input switching (INPUT DELAY) to
guarantee the correct timing during the Area Switching. This parameter allows handling
the delays caused by the activation and deactivation of Area Switching, which otherwise
could put the device in undesired or invalid and temporary switching zone input combi-
nations. As a consequence, this would cause the device to enter the fault state.
Zone Set Switching
2 Zone Sets
To make the device monitor two different Zone Sets, the user must configure the input
combination by selecting the signal “Area Switch”.
1. Enter 2 in “Zone Set no.” (Zone Sets Configuration step).
2. Choose the needed number of active inputs to create univocal combinations.
As an alternative, after entering the Zone Set number, press the coding icon to
automatically fill the area switches.
Zone Set 1
Area Switch 1 = 1, Area Switch 2 = 0;
Zone Set 2
Area Switch 1 = 0, Area Switch 2 = 1;
Figure 1 - 2 Zone Sets
As mentioned before, the Stand Alone and the Master models differ in the maximum
number of configurable Zone Sets. The Stand Alone model provides for up to six Zone
Sets and three inputs to be set as Area Switch; with the M12 12-pole Master model you
can have up to ten Zone Sets and five inputs for Area Switching. For more details, see
the sections below.