LEDS
USER MANUAL
9
LEDs
PWR
Shows the status of powered devices (off = no power; on = powered)
Q1
Shows the status of “out of temperature range” (Tenvironment < Tmin or
Tenvironment > Tmax). In such a case, Q1 blinks and the “ERR” LED lights up
steadily.
Q2
Shows the status of “generic failure” (i.e. any failure other than Q1 such as
motor block, voltage out of specifications, etc.). According to the internal
diagnostic system, if some critical diagnostic test fails, Q2 blinks and the
“ERR” LED lights up steadily.
ERR
Shows the status of device availability. If switched off, then the device is in
normal operation. If it’s steadily on, then it shows an error condition (see Q1
and Q2). If it’s blinking, it indicates that the device is not ready to measure yet
(i.e. at start-up).
Figure 11 - LGS-N50 LEDs
LED
MEANING