To connect M2xx and M3xx camera power, trigger signals, and strobe outputs, use cable 606-
0673-xx (12-pin to HD-15) with terminal block 661-0400.
NOTE 1: If Camera Trigger In requires a sinking signal, set the Software Trigger Event to Rising Edge. If it requires a
sourcing signal, set the Software Trigger Event to Falling Edge.
NOTE 2: If Strobe Trigger Output requires a sinking signal, set the Strobe Trigger Output to Falling Edge. If it requires a
sourcing signal, set the Strobe Trigger Output to Rising Edge.
Terminal
Signal Name
Notes
Camera Power Ground
Camera Ground
I/O Ground
I/O Ground
Camera Power +VDC
Camera Power
+12 to +24 VDC recommended
@ 500 mA Max
Maximum: +30 VDC
VCC
Power for Strobe Trigger Out
+3.3 to +24 VDC; 50 mA Max
Maximum: +30 VDC
Input 2 VCC
DO NOT USE
Not Currently Supported
Trigger VCC
Trigger In Pullup - use if Trig-
ger In needs sourcing input
Recommended: +24 VDC
Trigger In
Camera Trigger In (see Note
1 below)
0 to +24 VDC recommended
M30 VDC
As sinking input
Off: 0 to +1.4 VDC
On: +2.2 to +24 VDC; 5 to 15 ma
As sourcing input (see Trigger Pullup
+VCC)
Off: +2.2 to +24 VDC; 5 to 15 ma
On: 0 to +1.4 VDC
Input 2
DO NOT USE
Not Currently Supported
Strobe Trigger Out
Trigger Out to Strobe (see
Note 2 below)
DO NOT APPLY GROUND DIRECTLY
TO THIS OUTPUT.
Output 2
DO NOT USE
Not Currently Supported
Output 3
DO NOT USE
Not Currently Supported
Output 4
DO NOT USE
Not Currently Supported