Pullup Jumpers to Enable Sourcing
M-Series QuickStart Guide
Datalogic Automation, Inc.
Page 14
Pullup Jumpers to Enable Sourcing
Jumpers JP1 through JP16 enable and disable the connection between their respective Output and the “Outputs Sourcing
Pullups VCC” signal on the terminal block. If a jumper is in the Enable position, the Sourcing VCC is connected to the
Output and it provides a sourcing signal (it is normally low and goes high when On). If a jumper is in the Disable position,
the Output provides a sinking signal (normally high and goes low when On). The Discrete Output tool in the vision pro-
gram must be programmed to provide the desired output level. Refer to Discrete Output tool in the Impact Reference
Guide (843-0093).
General Purpose Output Circuit (Sinking)
NOTES
: To prevent output damage, all inductive loads must have noise suppressors connected directly across the load, as
close to the load as possible.
The 5 to +35 VCC terminal is not an output voltage source. An external power source must be connected to it.
This is not an output voltage source. An
external power source must be con-
nected to VCC, as indicated.
5 to +35 VCC is not an
output voltage source. An exter-
nal power source must be con-
nected to VDD, as indicated.