RS-232 INTERFACE FEATURES
ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
103
RS-232 ACK NAK Retry Count
This feature sets the number of times for the scanner to retry a label transmission under a
retry condition.
To set the RS
‐
232 ACK NAK Retry Count:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan the barcode,
Set RS-232 ACK NAK Retry Count
below. You’ll need to cover any
unused barcodes on this and the facing page to ensure that the scanner reads only
the barcode you intend to scan.
3. Scan the appropriate digits from the
Alpha-Numeric Keypad in Appendix C
that repre
‐
sent the desired number. The selectable range is 000
‐
255 resets. Pad all single and
double digit numbers with leading zeroes to yield a three
‐
digit entry (000
‐
255).
NOTE
A setting of 255 specifies “retry forever.”
4. The scanner will automatically exit Programming Mode when the appropriate
amount of digits have been scanned.
0608(CR)
Set RS-232 ACK NAK Retry Count
Default setting for this feature is:
003 - Three retrys
DEFAULT
Summary of Contents for Magellan 1500i
Page 1: ...MAGELLAN 1500i PRODUCT REFERENCE GUIDE Omni Directional Imaging Scanner...
Page 10: ...viii MAGELLAN 1500I NOTES...
Page 315: ...PRODUCT REFERENCE GUIDE 305 APPENDIX C ALPHA NUMERIC KEYPAD A B C D E F...
Page 317: ...PRODUCT REFERENCE GUIDE 307 9 0...
Page 344: ...COMPOSITE SAMPLE SYMBOLS 334 MAGELLAN 1500I NOTES...