IMAGING FEATURES
ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
71
Number of Imager Frames
This feature specifies the number of consecutive frames captured while using imager regis
‐
ter values to toggle between Near Field and Far Field performance. This can be used when a
greater depth of field is needed.
•
Byte0 = num frames using Set A
Byte1 = num frames using Set B
•
Byte0 = zero
Byte1 = zero: Toggling is disabled. Reg values for current mode used.
•
Byte0 = zero
Byte1 = nonzero: Reg values for toggle Set B always used.
•
Byte0 = nonzero
Byte1 = zero: Reg values for toggle Set A always used.
•
Byte0 = nonzero
Byte1 = nonzero: Reg values toggle between Set A and Set B.
To set this feature:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
below. You’ll need to cover any unused bar
‐
codes on this and the facing page to ensure that the scanner reads only the barcode
you intend to scan.
3. Scan the appropriate digits from the
Alpha-Numeric Keypad in Appendix C
4. Scan the Enter/Exit Programming Mode barcode at the top of the page to exit Pro
‐
gramming Mode.
150A(CR)
Set Number of Frames
Default setting for this feature is: 0 (Near Field)