ENTER/EXIT PROGRAMMING MODE
108
MAGELLAN™ 1500I
GLOBAL PREFIX/SUFFIX
Global Prefix
This feature applies to RS
‐
232 (Standard or Wincor
‐
Nixdorf), USB
‐
COM, USB
‐
TEC, and USB
Keyboard interfaces. It specifies the prefix that is added to the beginning of label transmis
‐
sion. To specify the Global Prefix Character(s):
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan the barcode Set Global Prefix below. Cover any unused barcodes to ensure the
scanner reads only the barcode you intend to scan.
3. Scan the appropriate characters/digits from the
Alpha-Numeric Keypad on page 305
that represent the hex designation for the desired character(s). The ASCII Character
Set and their corresponding Hex Values are in the inside back cover of this manual.
ASCII parameters must be input by scanning a pair of hexadecimal digits for each
character. To set a two
‐
character value of AB, barcodes containing the digits ‘4’, ‘1’, ‘4’,
and ‘2’ must be scanned. The selectable range for this option is any hex value from 00
to FF. Up to 20 hex pairs can be designated.
NOTE
To specify “No Global Prefix,” scan 00
4. If designating the full 20 hex pairs, the scanner will exit Programming Mode when the
appropriate amount of digits have been scanned. If designating less than 20 hex pairs,
you can end the programming sequence early by scanning the Terminate Sequence
barcode.
5. Complete the programming sequence by scanning the Enter/Exit Programming Mode
barcode.
031D(CR)
Set Global Prefix
Terminate Sequence
Default setting for this feature is:
00 - No Global Prefix
00000(CR)
DEFAULT
Summary of Contents for Magellan 1500i
Page 1: ...MAGELLAN 1500i PRODUCT REFERENCE GUIDE Omni Directional Imaging Scanner...
Page 10: ...viii MAGELLAN 1500I NOTES...
Page 315: ...PRODUCT REFERENCE GUIDE 305 APPENDIX C ALPHA NUMERIC KEYPAD A B C D E F...
Page 317: ...PRODUCT REFERENCE GUIDE 307 9 0...
Page 344: ...COMPOSITE SAMPLE SYMBOLS 334 MAGELLAN 1500I NOTES...