Aztec Length 1, Length 2 Programming Instructions
If Aztec Length Control is set to Fixed
‐
Length decoding, this feature specifies Aztec first
fixed length. If Aztec Length Control is set to Variable
‐
Length decoding, this feature speci
‐
fies the minimum label length.
NOTE
Length 1 is the minimum label length if in variable length mode, or the
first fixed length if in fixed length mode. Length 2 is the maximum label
length if in variable length mode, or the second fixed length if in fixed
length mode. Length includes the barcode's data characters only. Any
value > 3700 will be considered to be 3700.
To set this feature:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan the barcode,
Set Aztec Length 1 on page 281
Set Aztec Length 2 on page 281
below. You’ll need to cover any unused barcodes on this and the facing page to ensure
that the scanner reads only the barcode you intend to scan.
3. Scan the appropriate digits from the
Alpha-Numeric Keypad in Appendix C
that repre
‐
sent the desired label length. The selectable range for this option is 0001 to 3700. Pad
all numbers with leading zeros to yield a four
‐
digit entry (0001
‐
3700).
4. Complete the programming sequence by scanning the ENTER/EXIT Programming
Mode barcode.
0433(CR)
Set Aztec Length 1
Default setting for this feature = 0001
0434(CR)
Set Aztec Length 2
Default setting for this feature = 0E74 (length = 3700)
Summary of Contents for Magellan 1500i
Page 1: ...MAGELLAN 1500i PRODUCT REFERENCE GUIDE Omni Directional Imaging Scanner...
Page 10: ...viii MAGELLAN 1500I NOTES...
Page 315: ...PRODUCT REFERENCE GUIDE 305 APPENDIX C ALPHA NUMERIC KEYPAD A B C D E F...
Page 317: ...PRODUCT REFERENCE GUIDE 307 9 0...
Page 344: ...COMPOSITE SAMPLE SYMBOLS 334 MAGELLAN 1500I NOTES...