Sleep Mode Timer
This feature specifies the amount of time of inactivity (with no label reads) before the scan
‐
ner enters sleep mode.
To set this feature:
1. Scan the Enter/Exit Programming Mode barcode at the top of the page.
2. Scan the barcode
below. You’ll need to cover any unused bar
‐
codes on this and the facing page to ensure that the scanner reads only the barcode
you intend to scan.
3. Scan the appropriate digits from the
Alpha-Numeric Keypad in Appendix C
to represent
the desired time interval. The selectable range is 000
‐
255 in 15 second increments.
Pad all numbers with leading zeros to yield a three
‐
digit entry (000
‐
255).
4. Scan the Enter/Exit Programming Mode barcode at the top of the page to exit Pro
‐
gramming Mode.
03AF(CR)
Set Sleep Mode Timer
Default setting for this feature is: 5 minutes