Quick Reference Guide
3
Power Supply
Models require
1
either a Listed class II or class III with a Limited
Power Source (LPS). For the safety certification to be valid, class
III input power sources must be IEC/EN60950-1 (EN 60335-
series, EN 60065 or relevant) approved.
Input: 100 - 240 VAC
Output: 12 VDC
Max. Current: 1.5 A
Max. Power: 18 W
How to Scan
Bar codes can either be presented to the scanner’s window or
pushed past it using a “sweep” technique. The scanner can altena-
tively be programmed to initiate a scan of a cell phone or other
LCD bar code object, or an image capture upon pushing the
Camera Push Button. See the PRG for more details.
1. Power Off the Terminal (POT) units do not require a power supply.
1. Product
4. Sweeping motion
2. Scan Window
5. Presentation motion
3. Bar code
1
2
3
4
5
1
2
3
Atención
Características de la
fuente de alimentación
eléctrica.
Entrada: 100 - 240 Vca
600mA 50/60 Hz
Salida: +12 VDC 1500mA.
(-) Negativo al centro
Utilice en su red solo fuentes certificadas
en Argentina.
El uso de fuentes de alimentación no
compatibles puede resultar en riesgo de
incendio o de choque eléctrico para el
usuario.