Product Reference Guide
173
Appendix F
Host Commands
Accepting RS-232 Commands
The scanner responds to the following RS-232 commands:
COMMAND
ASCII
HEX
COMMENT
Enable Scan-
ner
E
0x45
Disable
Scanner
D
0x44
Reset Scanner
R
0x52
Not On File
Indication
F
0x46
Long series of beeps
Beep Good
Read Tone
B
0x42
Beeps if Good Read Beep is enabled
Force Good
Read Tone
!
0x01
Beeps regardless of beep setting
Identification
request
i
0x69
Returns long response
a
a. Call Tech Support for information.
Health
request
h
0x68
Returns long response
Status
request
s
0x73
Returns long response
If one of the above commands is received, the scanner will perform the steps
indicated for the command. Host commands for other interfaces are also avail-
able. Contact Tech Support for more details.
Also see the section
"Image Capture to the Host by Host Command"
for details concerning that feature.
Summary of Contents for MAGELLAN 3200VSI
Page 1: ...Magellan 3200VSi Product Reference Guide...
Page 16: ...8 Magellan 3200VSI NOTES...
Page 40: ...Enter Exit Programming Mode 32 Magellan 3200VSI Wake Up Intensity continued 13 14 15...
Page 46: ...Enter Exit Programming Mode 38 Magellan 3200VSI NOTES...
Page 80: ...USB COM Interface Setup 72 Magellan 3200VSI NOTES...
Page 92: ...Enter Exit Programming Mode Character Conversion 84 Magellan 3200VSI NOTES...
Page 163: ...Product Reference Guide 155 Appendix C A B C D E F Alpha Numeric Pad...
Page 180: ...172 Magellan 3200VSI NOTES...
Page 182: ...174 Magellan 3200VSI NOTES...
Page 192: ...184 Magellan 3200VSI NOTES...