USER LICENSE AGREEMENT

Notice to End User: The Datalogic Product you have acquired contains embedded Soft-
ware, which is integral to the product's operation. This Software is being provided to
you under license, subject to the terms and conditions of this Agreement. If you use the
Datalogic Product, you will be deemed to have accepted the terms and conditions of this
Agreement. If you do not intend to be bound to the terms of this Agreement, Datalogic is
not willing to license the Software to you, you may not use the Datalogic Product or the
Software, and you must contact the party from whom you acquired the Datalogic Product
for instructions.

This End User Software License Agreement ("Agreement") is a legally binding agreement gov-
erning the licensing of the Software and Documentation by Datalogic,Scanning Holdings, Inc.
and its subsidiaries and affiliates ("Datalogic") to the entity or person who has purchased or oth-
erwise acquired a Datalogic Product ("End User"). For purposes of this Agreement, any soft-
ware that is associated with a separate end-user license agreement is licensed to you under the
terms of that license agreement. Datalogic and End User hereby agree as follows:

1. Definitions.

1.1

"Documentation" means materials such as user's guides, program reference guides,
quick reference guides, manuals, or similar materials associated with or related to the
Datalogic Product, whether in printed, "online", or other form.

1.2

"Proprietary Information" means: (a) source code, object code, software, documentation,
and any related internal design, system design, data base design, algorithms, technol-
ogy, technical data or information, implementation techniques, and trade secrets related
to the Software, (b) any other trade secrets marked appropriately or identified as proprie-
tary or confidential, and (c) any information that End User, under the circumstances,
should recognize as confidential. Proprietary Information does not include any informa-
tion that the receiving party can establish was (1) in the public domain, (2) already in the
receiving party's possession or rightfully known prior to receipt, (3) rightfully learned from
a third party not in violation of any other's proprietary rights, or (4) independently devel-
oped without access to Proprietary Information.

1.3

"Datalogic Product" means the Datalogic Magellan

TM

1000i series, Magellan

TM

1100i

series, Magellan

TM

1400i series, Magellan

TM

2200VS series, Magellan

TM

2300HS series,

Magellan

TM

3200VSi series, Magellan

TM

3300HSi series, Magellan

TM

8100 series,

Magellan

TM

8200 series, Magellan

TM

8300 series, Magellan

TM

8400 series, Magellan

TM

8500 series, Magellan

TM

9500 series, and/or Magellan SL

TM

series scanner and/or scan-

ner/scale product, including all embedded Software in and all Documentation related to
such product, which has been purchased or otherwise acquired by End User, whether
obtained directly or indirectly from Datalogic.

1.4

"Software" means any software or computer programs of Datalogic or its third party licen-
sors in machine readable form which is embedded in the Datalogic Product, whether
obtained directly or indirectly from Datalogic, including any replacement, update,
upgrade, enhancement or modification.

2. Scope Of License Granted.

2.1

Datalogic grants to End User a non-exclusive, non-transferable, perpetual license to use
the Software, solely on the Datalogic Product in which it is embedded ("designated Data-
logic Product"), in machine-readable form only, solely for End User's internal business
purposes. This Agreement does not convey ownership of the Software to End User.
Title to the Software shall be and remain with Datalogic or the third party from whom Dat-
alogic has obtained a licensed right. As used in this Agreement, the term "purchase" or
its equivalents when applied to the Software shall mean "acquire under license." End
User is not entitled to receipt or use of the source code to any Software.

2.2

End User shall not copy, modify, decompile, disassemble, reverse engineer, or otherwise
reproduce or remanufacture the Software, whether modified or unmodified, nor sell,
assign, sublicense, distribute, lend, rent, give, or otherwise transfer the Software to any

Summary of Contents for Magellan 3300HSi

Page 1: ...MagellanTM 3300HSi Omni Directional Imaging Scanner Quick Reference Guide...

Page 2: ...ire printed versions by contacting your Datalogic representative Electronic versions may either be downloadable from the Datalogic website www scanning datalogic com or provided on appropriate media I...

Page 3: ...enclature 1 Installation 2 Power Supply 3 How to Scan 3 Troubleshooting 4 Productivity Index Reporting Option 5 Scanner Push Button 5 LED and Beeper Indicators 7 Error Codes 9 Going Green 11 Bar Code...

Page 4: ...ii MagellanTM 3300HSi NOTES...

Page 5: ...nforma tion that the receiving party can establish was 1 in the public domain 2 already in the receiving party s possession or rightfully known prior to receipt 3 rightfully learned from a third party...

Page 6: ...nd User acquires no right or interest in any Proprietary Information 5 2 End User shall not disclose provide or otherwise make available the Proprietary Infor mation of Datalogic or its third party li...

Page 7: ...INFRINGEMENT CANCELS AND SUPERSEDES ANY PRIOR AGREE MENTS WHETHER ORAL OR WRITTEN BETWEEN THE PARTIES CONCERNING SUCH CLAIMS AND WILL NOT BE MODIFIED OR AMENDED BY ANY PAST CON TEMPORANEOUS OR FUTURE...

Page 8: ...ng and shall be effective when received with evidence of receipt Notices to Datalogic shall be sent to the attention of Contract Administration Datalogic Scanning Holdings Inc 959 Terry Street Eugene...

Page 9: ...n reference the Product Reference Guide PRG which is available for viewing and download from the Datalogic website listed on the back cover of this manual Labeling and Nomenclature Figure 1 Labeling a...

Page 10: ...or flash its good read LED1 and send the bar code data to the host or terminal If not use the Troubleshooting sec tion of this guide to identify any prob lems Remove the Top Cover and use the lift ha...

Page 11: ...C Output 12 VDC Max Current 1 5 A Max Power 18 W How to Scan The scanner is mounted flush with the counter to allow items to be slid or pushed over its top in the direction of the arrow as shown in Fi...

Page 12: ...attached to the host and the scanner The scanner will not read bar codes at all or reads poorly Make sure the window is clean Check that the bar codes are of sufficient quality to be recognized by th...

Page 13: ...r please refer to the Product Reference Guide PRG Scanner Push Button The Scanner Push Button also performs multiple functions depending upon the duration of time it is pressed NOTE Volume changes mad...

Page 14: ...hree tones Stop when the desired tone high medium or low is sounded 4 Seconds Scanner Diagnostics Modea This mode allows system sup port personnel to troubleshoot problems with the scanner and is used...

Page 15: ...Power on indication Bright green flash Indicates the scanner has finished all its power up tests and is now ready for operation Good Read Indication Bright green flash Indicates a barcode has been rea...

Page 16: ...hed all its power up tests and is now ready for oper ation Good Read Indication Single beep The good read beep indication is configu rable Options include Enable disable frequency duration and volume...

Page 17: ...f it is configured to do so the scanner will sound a series of beeps corresponding to the error code and or flash its LED simultane ous to the beeps The table below describes what these codes mean and...

Page 18: ...10 MagellanTM 3300HSi NOTES...

Page 19: ...oing Green Thank you for using the bar code mask on the opposite side of this page This manual has been formatted to minimize the quantity of pages needed to provide all of the program ming bar codes...

Page 20: ...from the manual as indicated to create a sleeve through which bar codes start ing on the following page can be individually viewed and scanned It is important that only one bar code at a time be prese...

Page 21: ...Scan a Start End bar code once to enter Programming Mode After selecting scanning the interface scan the ENTER EXIT barcode a second time which will then accept your changes exit Programming Mode and...

Page 22: ...14 MagellanTM 3300HSi IBM 4683 Port 5B IBM 4683 Port 9B IBM 4683 Port 17 USB OEM START END...

Page 23: ...de 15 USB Keyboard USB COM Interface Keyboard Wedge A PC XT w alternate Key Encoding NOTE If other than Keyboard Wedge A with USA keyboard is needed see the PRG or On Screen Programming for additional...

Page 24: ...user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Con...

Page 25: ...o the limitations and exclusions set forth in the paragraphs that follow WARRANTY SET FORTH ABOVE IS IN LIEU OF ANY OTHER WARRAN TIES EXPRESS OR IMPLIED INCLUDING MERCHANTABILITY AND FITNESS Exclusion...

Page 26: ...TICE OF THE POSSIBILITY OF SUCH DAMAGES Assignment Customer may not assign or otherwise transfer its rights or obliga tions under Warranty except to a purchaser or transferee of prod uct No attempted...

Page 27: ...ards EN 55022 2007 EMC EN 55024 2003 Immunity EN 60950 1 2006 All 2009 ITE Safety EN 61000 3 2 2006 Harmonic Current EN 61000 3 3 2005 Voltage Fluctuation Flicker EquipmentType Barcode Scanning Equipm...

Page 28: ...gic Scanning India Telephone 91 22 64504739 india scanning datalogic com Italy Datalogic Scanning SpA Telephone 39 0 39 62903 1 italy scanning datalogic com Japan Datalogic Scanning KK Telephone 81 0...

Reviews: