Product Reference Guide
63
Single Cable RS-232 RTS CTS Selection
Specifies how RTS and CTS are used to control the data flow. RTS is controlled
by the Scanner and can be continuously held high/low, or can be asserted
during label transmission. The scanner looks at CTS, as the configuration val-
ues state, to determine when to send label data.
Choices are:
• Option 0 = RTS is held in low state and CTS is ignored
• Option 1 = RTS is held in high state and CTS is ignored
• Option 2 = Assert RTS and wait for CTS to be asserted
• Option 3 = Assert RTS and ignore CTS
• Option 4 = RTS held low, wait for CTS to be asserted
• Option 5 = RTS held high, wait for CTS to be asserted
START / END
PROGRAMMING bar codes
RTS CTS Selection =
RTS is held in low state and CTS is ignored
RTS CTS Selection =
RTS is held in high state and CTS is ignored
RTS CTS Selection =
Assert RTS and wait for CTS to be asserted
RTS CTS Selection =
Assert RTS and ignore CTS
RTS CTS Selection =
RTS held low, wait for CTS to be asserted
RTS CTS Selection =
RTS held high, wait for CTS to be asserted
DEFAULT
Summary of Contents for Magellan 3300HSi
Page 1: ...MagellanTM 3300HSi In Counter Horizontal Single Plane Scanner Product Reference Guide...
Page 42: ...34 Magellan 3300HSI NOTES...
Page 84: ...76 Magellan 3300HSI NOTES...
Page 96: ...88 Magellan 3300HSI NOTES...
Page 160: ...152 Magellan 3300HSI NOTES...
Page 168: ...160 Magellan 3300HSi Scanner Dimensions 3 42 8 69cm 6 15 24cm 6 15 24cm...
Page 170: ...162 Magellan 3300HSi NOTES...
Page 173: ...Product Reference Guide 165 Appendix C Alpha Numeric Pad A B C D E F...
Page 192: ...184 Magellan 3300HSi NOTES...
Page 214: ...206 Magellan 3300HSi NOTES...