Micro QR Code Length Control
Enter/Exit Programming Mode
Product Reference Guide
277
Micro QR Code Length 1, Length 2 Programming Instructions
If Micro QR Code Length Control is set to Fixed-Length decoding, this feature
specifies Micro QR Code first fixed length. If Micro QR Code Length Control is
set to Variable-Length decoding, this feature specifies the minimum label
length.
NOTE
Length 1 is the minimum label length if in variable length
mode, or the first fixed length if in fixed length mode. Length 2
is the maximum label length if in variable length mode, or the
second fixed length if in fixed length mode. Length includes
the bar code's data characters only. Any value > 3700 will be
considered to be 3700.
To set this feature:
1. Scan the ENTER/EXIT Programming Mode bar code.
2. Scan the bar code,
Set Aztec Length 1 on page 280
below. You’ll need to cover any unused bar codes
on this and the facing page to ensure that the scanner reads only the bar
code you intend to scan.
3. Scan the appropriate digits from the
Alpha-Numeric Keypad in Appendix C
that represent the desired label length. The selectable range for this
option is 0001 to 3700. Pad all numbers with leading zeros to yield a four-
digit entry (0001-3700).
4. Complete the programming sequence by scanning the ENTER/EXIT Pro-
gramming Mode bar code.
Default setting for this feature = 0001
042B(CR)
Set Micro QR Code Length 1
042C(CR)
Set Micro QR Code Length 2
Default setting for this feature = 0E74
Summary of Contents for Magellan 3450VSi
Page 1: ...Magellan 3450VSi Omni Directional Imaging Scanner Product Reference Guide ...
Page 16: ...Mount Installation 6 Magellan 3450VSi NOTES ...
Page 44: ...Enter Exit Programming Mode Host Download to Handheld 34 Magellan 3450VSi NOTES ...
Page 64: ...Imaging Features 54 Magellan 3450VSi NOTES ...
Page 106: ...Enter Exit Programming Mode USB Keyboard Intercharacter Delay 96 Magellan 3450VSi NOTES ...
Page 266: ...Standard 2 of 5 256 Magellan 3450VSi NOTES ...
Page 302: ...Error Codes 292 Magellan 3450VSi NOTES ...
Page 304: ...Standard Cable Pinouts Primary Interface Cables 294 Magellan 3450VSi NOTES ...
Page 305: ...Product Reference Guide 295 Appendix C Alpha Numeric Keypad A B C D E F ...
Page 322: ...312 Magellan 3450VSi NOTES ...
Page 330: ...Accepting RS 232 Commands 320 Magellan 3450VSi NOTES ...
Page 340: ...microSD Function Details 330 Magellan 3450VSi NOTES ...
Page 350: ...Handheld Data Format Requirements General 340 Magellan 3450VSi NOTES ...