background image

16

Magellan™ 3500HSi

Warranty

Datalogic warrants to Customer that this product will be free from defects in materials and 
workmanship for a period of 3 years from product shipment.
Datalogic warrants that the goods delivered under these General Terms for the Sale of 
Goods shall be free from defects in materials and workmanship under normal and proper 
use during the Warranty Period (as defined below). Datalogic’s liability under this warranty 
is limited to furnishing the labor and parts necessary to remedy any defect covered by this 
warranty and restore the product to its normal operating condition. Repair or replacement 
of product during the warranty does not extend the original warranty term. Products are 
sold on the basis of specifications applicable at the time of manufacture and Datalogic has 
no obligation to modify or update products once sold. The warranty period shall extend 
from the date of shipment from Datalogic for the duration published by Datalogic for the 
product at the time of purchase (“Warranty Period”).
If, during the Warranty Period, Datalogic determines that a product has defects in material 
or workmanship, Datalogic shall, at its sole option repair or replace the product without 
additional charge for parts and labor, or give a credit for the defective products duly 
returned to Datalogic. To perform repairs, Datalogic may use new or reconditioned parts, 
components, subassemblies or products that have been tested as meeting applicable 
specifications for equivalent new material and products. Buyer will allow Datalogic to 
scrap all parts removed from the repaired product. Datalogic warrants repaired hardware 
devices only, against defects in workmanship and materials on the repaired assembly for a 
90 day period starting from the date of shipment of the repaired product from Datalogic or 
until the expiration of the original Warranty Period, whichever is longer. Datalogic does not 
guarantee, and it is not responsible for, the maintenance of, damage to, or loss of configu-
rations, data, and applications on the repaired units and at its sole discretion can return 
the units in the “factory default” configuration or with any software or firmware update 
available at the time of the repair (may be newer than the firmware or software installed 
during the manufacture of the product). Buyer accepts responsibility to maintain a backup 
copy of its software and data. 

Warranty Exclusions

The Datalogic Warranty shall not apply to:

(i) 

any product which has been damaged, modified, altered, repaired or upgraded by 
other than Datalogic service personnel or its authorized representatives;

(ii) 

defects or damages caused by any third parties’ tort committed against the 
Buyer.

(iii) 

any claimed defect, failure or damage which Datalogic determines was caused by 
faulty operations, improper use, abuse, misuse, wear and tear, negligence, 
improper storage or use of parts or accessories not approved or supplied by Dat-
alogic;

(iv) 

any claimed defect or damage caused by the use of product with any other 
instrument, equipment or apparatus;

(v) 

any claimed defect or damage caused by the failure to provide proper mainte-
nance, including but not limited to cleaning the upper window in accordance with 
product manual or the replacement of upper window/cartridge due to scratching, 
stain or other degradation;

Summary of Contents for Magellan 3500HSi

Page 1: ...Magellan 3500HSi Omni Directional Imaging Scanner Quick Reference Guide ...

Page 2: ...be published you can acquire printed ver sions by contacting your Datalogic representative Electronic versions may either be downloadable from the Datalogic website www datalogic com or provided on appropriate media If you visit our website and would like to make comments or suggestions about this or other Datalogic publications please let us know via the Contact Datalogic page Disclaimer Datalogi...

Page 3: ... How to Scan 4 Scanner Button 4 LED and Beeper Indicators 6 Troubleshooting 8 Error Codes 9 Programming 10 Interface Selection 10 Cell Phone Mode 12 Cell Mode Percent 13 Cleaning 14 Manufacturer Approved Cleaning Materials 15 Warranty 16 Going Green 19 Bar Code Mask 20 ...

Page 4: ...ii Magellan 3500HSi NOTES ...

Page 5: ...ming information reference the Product Reference Guide PRG which is available for viewing and download from the Datalogic website listed on the back cover of this manual Features Figure 1 Scanner Features Front View Top Cover Scan Connector Ports Window Speaker Grille Cover Removal Scanner Lift Handles Indentation USB Micro B MicroSD Card Button Regulatory Ser Number label shown in Figure 2 below ...

Page 6: ... the unit as shown in b of the illustration The scanner will go through its power up routine which may take longer than 10 seconds After it is complete scan some known good bar code samples to verify correct operation The scanner should beep and or flash its good read LED1 and send the bar code data to the host or termi nal If not use the Troubleshooting section of this guide to identify any probl...

Page 7: ...Quick Reference Guide 3 Figure 3 Scanner Cabling U S B R S 232 To Terminal PC RS 232 and USB Cables Powered by AC Adapter Power Off the Terminal POT Terminal PC USB Power a b ...

Page 8: ...scan rate Figure 4 Scanning Items Scanner Button The Scanner Button performs multiple functions depending on how long it is pressed NOTE Volume changes made using the Scanner Button are lost when the scanner is powered down and reset to the con figured setting If you wish to permanently change the volume use the special programming labels in the Prod uct Reference Guide Product Bar Code LED Indica...

Page 9: ...eper sounds Increments tone Press the button for approxi mately 2 seconds then release Each time this is done the beeper will sound at one of three tones Stop when the desired tone high medium or low is sounded 4 Seconds Scanner Diagnostics Modea This mode allows system sup port personnel to troubleshoot problems with the scanner and is used to determine if it can read bar codes Press the but ton ...

Page 10: ...flash Indicates a bar code has been read and decoded Scanner Ready Constant dim green The scanner is ready for operation Sleep Mode The green LED alternates from brief blinks to lon ger dark periods repeating at about 0 5 Hz The scanner is in Sleep Mode To wake the scanner up move an object in front of its window or press the button atop the unit This indication is optionally configurable and may ...

Page 11: ...ble frequency duration and volume See the Product Reference Guide PRG for more information Diagnostics Varies see Error Codes on page 9 for more informa tion The Beeper can provide diagnostic feedback if the scanner discovers a problem during SelfTest Programming Mode Indications Varies depend ing upon the fea ture s being configured The Beeper will sound as programming bar code labels are scanned...

Page 12: ...and the scanner The scanner will not read bar codes at all or reads poorly Make sure the window is clean Check that the bar codes are of sufficient quality to be recognized by the scanner Wrinkled smudged or torn labels can cause the scan ner to not read at all Scan known good labels of an active symbology a to check the scanner s read operation If the scanner still does not function properly cons...

Page 13: ...curs press the Scanner button to hear the error code If it is configured to do so the scanner will sound a series of beeps corresponding to the error code and or flash its LED simultaneous to the beeps NUMBER OF LED FLASHES BEEPS ERROR CORRECTIVE ACTION 1 Configuration Contact Helpdesk for assistance 2 Host Interface 6 Main PCB 10 Button Error 11 USB Device 13 CPLD ID ...

Page 14: ...ce to enter Program ming Mode After scanning the programming label for the desired inter face scan the START END barcode a second time to accept your changes exit Programming Mode and return the scanner to normal operation You can select other options and customize your scanner through use of the instructions and programming bar codes available in the PRG or use the On Screen Programming OSP utili...

Page 15: ...Quick Reference Guide 11 USB OEM USB Keyboard USB COM Interface NOTE Reference the Product Reference Guide PRG or On Screen Programming for additional options START END 000145 CR 000135 CR 000147 CR ...

Page 16: ...12 Magellan 3500HSi Cell Phone Mode Enables disables mobile phone barcode reading START END Cell Phone Mode Disable Cell Phone Mode Enable Always On 046701 CR 046702 CR DEFAULT ...

Page 17: ...ode must be enabled for this to be active NOTE Settings above 10 will slow down read performance on printed barcodes START END Cell Mode Percent 2 5 Very Low Cell Mode Percent 5 Low Cell Mode Percent 10 Medium Cell Mode Percent 20 Med High Cell Mode Percent 50 High DEFAULT 047100 CR 047101 r 047102 r 047103 r 047104 r ...

Page 18: ...rasive mild water based cleaner to wipe away stains smudges fingerprints spills etc from the scan window and exterior sur faces See the next page for a list of Manufacturer Approved Cleaning Materials CAUTION DO NOT use abrasive cleaning agents or abrasive pads to clean this product Harsh chemicals disinfec tants and cleansers can cause damage which will adversely affect scanning performance CAUTI...

Page 19: ...combina tion with other cleaning agents will void the manufacturer s war ranty APPROVED CLEANERS Hydrogen Peroxide not to exceed a 3 solution Chlorine bleach not to exceed a 0 25 solution Mild detergent and water lsopropyl Alcohol not to exceed a 70 solution CAUTION Use of above cleaners in combination with each other is not recommended and may constitute a health hazard Follow all specified safet...

Page 20: ...to scrap all parts removed from the repaired product Datalogic warrants repaired hardware devices only against defects in workmanship and materials on the repaired assembly for a 90 day period starting from the date of shipment of the repaired product from Datalogic or until the expiration of the original Warranty Period whichever is longer Datalogic does not guarantee and it is not responsible fo...

Page 21: ... Datalogic such opportunity shall constitute acceptance by Buyer and waiver of all claims for defects The products must always be returned within ten 10 days from the date of authorization issued by Datalogic If Datalogic determines Buyer s claim is valid Datalogic will repair or replace product without additional charge for parts and labor Buyer shall be responsible for packaging and shipping the...

Page 22: ...ise in default under or in repudiation of this contract or any other con tract with Datalogic or fails to pay when due any invoice under this contract then in addition to any and all remedies allowed by law Datalogic without notice may 1 bill and declare due and payable all undelivered products under this or any other contract between Datalogic and the Buyer and or 2 defer shipment under this or a...

Page 23: ... 19 Going Green Thank you for using the bar code mask on the opposite side of this page This manual has been formatted to minimize the quantity of pages needed to provide the programming bar codes available for this product ...

Page 24: ...s page and remove it from the manual as indicated to cre ate a sleeve through which bar codes can be individually viewed and scanned It is important that only one bar code at a time be presented to the scanner Bar Code Mask Sheet Bar Code Manual folded ...

Page 25: ...Quick Reference Guide 21 NOTES ...

Page 26: ...22 Magellan 3500HSi NOTES ...

Page 27: ......

Page 28: ...ntroduced into a retrieval system or transmitted in any form or by any means or for any purpose with out the express written permission of Datalogic S p A and or its affili ates Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S and the E U Datalogic S r l Via S Vitalino 13 40012 Lippo di Calderara di Reno Bologna Italy Tel 39 051 3147...

Reviews: