Enter/Exit Programming Mode
Code 128
92
Magellan™ 800i Scanner
Code 128 Conversion to Code 39
Enables/disables expansion of Code 128 labels to Code 39. When enabled, the
label identifier for a Code128 label shall be set to Code 39 and all Code 39 for-
matting control shall be applied to the label.
069600(CR)
Disable
DEFAULT
Enable
069601(CR)
Code 128 Stitching
Enables/disables stitching for Code 128 labels. When parts of a Code 128 bar
code are presented to the scanner with this feature enabled, the bar code parts
will be assembled by the scanner’s software, and the data will be decoded if all
bar code proofing requirements are met.
06A800(CR)
Disable Code 128 Stitching
Enable Code 128 Stitching
DEFAULT
06A801(CR)