Product Reference Guide
6-273
Standard 2 of 5 Minimum Label Length
This feature specifies the minimum allowable length of an Standard 2 of 5
label.
To set this feature:
1. Scan the SWITCH barcode.
SET STANDARD 2 OF 5 MINIMUM LABEL
below. You’ll need to cover any unused barcodes on this
and the facing page to ensure that the scanner reads only the bar-
code you intend to scan.
3. Scan the appropriate digits from the keypad in
that rep-
resent the desired minimum label length. The selectable range for
this option is 01 to 50, even numbers only. Pad all single digit num-
bers with a leading zero to yield a two-digit entry (01-50).
4. Complete the programming sequence by scanning the SWITCH
barcode.
SET STANDARD 2 OF 5 MINIMUM LABEL LENGTH
NOTE
Length in this case includes check and data characters, but does not
include start or stop characters. This feature applies when
is set to variable-length decoding.
Minimum label length should be less than or equal to maximum label
length.
Summary of Contents for MAGELLAN 8500?
Page 1: ...Magellan 8500 Product Reference Guide...
Page 14: ...12 Magellan 8500 Scanner NOTES...
Page 66: ...2 36 Magellan 8500 Scanner NOTES...
Page 84: ...3 18 Magellan 8500 Scanner Figure 3 6 Removing Replacing the Gasketed DLC Window a b c d...
Page 89: ...Product Reference Guide 4 5 Figure 4 1 7 Segment LED Display 7 Segment Display Models vary...
Page 98: ...4 14 Magellan 8500 Scanner NOTES...
Page 420: ...D 2 Magellan 8500 Scanner NOTES...
Page 436: ...E 16 Magellan 8500 Scanner NOTES...
Page 452: ...F 16 Magellan 8500 Scanner NOTES...
Page 453: ...Product Reference Guide F 17 NOTES...
Page 454: ...F 18 Magellan 8500 Scanner NOTES...