Product Reference Guide
A-9
Scale Zero Push Button
The Scale Zero Push Button is used for multiple functions as listed in
.
NOTE
The Scale Zero Push Button has no function in a “scanner only”
model.
Table 1-4. Scale Zero Push Button Functions
PRESS
DURATION
FUNCTION
COMMENT
Momentary
Zero Scale
When programmed to do so, the yellow LED should be lit when no
weight is on the scale, indicating scale at zero. If it is not, press the
switch to zero the scale. The unit will sound a “click” upon pressing
the button.
4 Seconds
Scale Diagnostics
Mode
a
This mode allows system support personnel to troubleshoot prob-
lems with the scale. Momentarily press the Scale Zero Push Button
or cycle power to exit Scale Diagnostics Mode.
8 Seconds
Resets Scanner
Only system support personnel
a. Diagnostics Mode is meant for use by trained systems support personnel. Users should not need to ini-
tiate this function under normal circumstances.