background image

Controls and Indicators

Quick Reference Guide

  

                   5

Controls and Indicators

The scanner features a conspicuous green LED indicator bar atop the control panel side 

of its vertical “bonnet” (item #2 in Figure 4). Additionally, a configurable speaker is used 

to sound scanning, weighing and EAS deactivation indications, ScaleSentry event, etc.

Figure 4. Top Side LED Indicators

1

2

3

4

5

6

7

1

LED Indicator ”Bar”

5

Manual EAS Deactivation 

Button

2

Scanner Control Button

b

6

Scale Sentry Override 

Button

3

Scale Zero Button

7

Speaker 

4

Camera Button

Table 1. Control Panel

See 

LED and Beeper Indications

 for more information regarding each of the indicators.

1

LED Indicator Bar

5

Manual EAS Deactivation Button

This bar lights/flashes to indicate functions such as a good 

read, ScaleSentry event, etc.

When in EAS Manual Deactivation Mode, 

push this button to deactivate an item.

The LED illuminates to indicate EAS func-

tions with red, green OR orange color.

2

Scanner Control Button

6

ScaleSentry Override Button

-If the scanner is “asleep”, press this button to wake it up.

-Press this button momentarily to enter beeper volume 

change state. Select one of five volume settings.

-Press this button between 1 and 4 seconds to enter beeper 

tone change state.

-Press this button for 10 seconds to initiate a soft reset.

When configured to do so, a push of this 

button will override a detected scale over-
hang condition.

This red LED indicates the current 

ScaleSentry condition. See the 

LED and 

Beeper Indications

 section for more 

information.

3

Scale Zero Button

7

Speaker

With all weight removed from the scale, push this button to 

set the scale to zero.

The yellow LED indicates scale functions.

Sounds

a

 beeps, error tones and other audi-

ble signals to indicate good read, 
ScaleSentry alert, system error and other 
conditions.

4

Image Capture Button

This button is used to capture images using the vertical 

window. See the PRG for more information.

.

a. Some audible indications are configurable to be on or off, as well as offer their own programmable 

options for pitch, volume, etc.

b. Button functions may be disabled for some applications based on user requirements. See the pro-

gramming section of the PRG for details.

Summary of Contents for Magellan 9400i

Page 1: ...MagellanTM 9300i and 9400i Scanner and Scanner Scale with Imaging Technology Quick Reference Guide...

Page 2: ...e downloadable from the Datalogic website www datalogic com or provided on appropriate media If you visit our website and would like to make comments or suggestions about this or other Datalogic publi...

Page 3: ...TM Option 4 Electronic Article Survellance EAS Deactivation Options 4 Sensormatic Coupled Mode 4 Sensormatic Decoupled Mode 4 Sensormatic Hybrid Mode 4 Controls and Indicators 5 Cleaning 6 CSS Option...

Page 4: ...ii MagellanTM 9300i and 9400i NOTES...

Page 5: ...seamlessly without requiring item orientation by the cashier This manual describes basic operation For more detailed information about setup installa tion and programming see the Product Reference Gui...

Page 6: ...el is affixed to the unit Depending upon the size and shape of the label placement can be made in one of the locations shown in Figure 1 Figure 1 Affixing the Scale Certification Label 1 2 3 5 6 4 1 L...

Page 7: ...lts Keep items in their natural orientation Don t favor any of the scan win dows Use the arrow guides to 6 in Figure 2 to center items over the horizontal window Push or slide items instead of lifting...

Page 8: ...LED indicator will illuminate to indicate a ScaleSentry error condition A scale transaction cannot be completed until the item s are repositioned to rest fully on the platter move them towards the cen...

Page 9: ...utton If the scanner is asleep press this button to wake it up Press this button momentarily to enter beeper volume change state Select one of five volume settings Press this button between 1 and 4 se...

Page 10: ...e which will adversely affect scanning and weighing performance Daily clean the debris chutes between the platter and the outer housing Figure 5c Most items can be cleared from the debris chutes by ca...

Page 11: ...ble Scanner Disabled Continuous blink 100ms ON 900ms OFF N A The Host has disabled scanning Sleep Mode 10ms ON 1990ms OFF N A The scanner has been inactive for a period and is in a power saving mode C...

Page 12: ...caleSentry beam is not blocked Sensormatic EAS Indications If the scanner is equipped with the optional Sensormatic EAS opton various deactivation and validation indications will be enabled INDICATION...

Page 13: ...a 90 day period starting from the date of shipment of the repaired product from Datalogic or until the expiration of the original warranty period whichever is longer Datalogic does not guarantee and...

Page 14: ...power supply batteries keypads touch screen triggers etc No Assignment Customer may not assign or otherwise transfer its rights or obligations under this warranty except to a purchaser or transferee...

Page 15: ......

Page 16: ...Eugene OR 97402 USA Telephone 1 541 683 5700 Fax 1 541 345 7140 2014 2015 Datalogic ADC Inc Inc All rights reserved Datalogic and the Datalogic logo are registered trademarks of Data logic S p A in ma...

Reviews: