MSI/Plessey Stitching
Enables/disables stitching for MSI/Plessey labels. When parts of an MSI/
Plessey bar code are presented to the scanner with this feature enabled, the
bar code parts will be assembled by the scanner’s software, and the data
will be decoded if all bar code proofing requirements are met.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan your selection from the bar codes below. You’ll need to cover
any unused bar codes on this and the facing page to ensure that the
scanner reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the SWITCH
bar code.
MSI/PLESSEY STITCHING = DISABLE
MSI/PLESSEY STITCHING = ENABLE
NOTE
MSI/Plessey Stitching operates using fixed lengths ONLY. MSI/Plessey Fixed
Length 1 and/or MSI/Plessey Fixed Length 2 must be properly configured for
stitching to work.