Scale Error Reporting
Product Reference Guide
4-5
Figure 4-1. 7-Segment LED Display
Scale Error Reporting
Scale diagnostics uses the Remote Scale Display and the Zero Status lamp
to communicate specific scale failures. The following chart shows the
Remote Display messages, the Scale Status lamp indication, the problem
that the scale is experiencing and what action should be taken. When
troubleshooting, always remember to check all cable connections first
before proceeding with other problem isolation steps.
7-Segment Display
Remote
Display
Scale Status
Lamp
Problem
Description
Action Required
E _1
Flash, pause, 1 blink,
long pause, repeat
sequence.
Too much motion at power-
up.
Check for stable installation. Change
scale motion filter using the labels
found in
Chapter 6
; restart. If prob-
lem persists, scale may require calibra-
tion.
E__2
Flash, pause, 2
blinks, long pause,
repeat sequence.
Calibration lost.
Call technical support personnel. Re-
calibrate; restart; recertify (if required).