Interface Type
Specifies the current scanner interface. Selections are:
INTERFACE (I/F)
TYPE
I/F I.D.
NUMBER
a
a. To access a scanner’s interface identification number, place the scanner in Scanner Diagnostic
Mode and view the 7-segment FRU display (reference
,
for
more information).
RS-232 Standard
05
RS-232 Wincor-Nix-
dorf
12
RS-232 Single Cable
20
USB OEM
45
IBM
Port 17
04
IBM
Port 5B
08
IBM
Port 9B
23
USB Keyboard
35
USB-TEC
0D
USB COM
47
NOT USER-SELECTABLE
System Interface
7-segment FRU
display indi-
cates 0 at start-
up (accompa-
nied by trill beep
for approx. 2
seconds)