Magellan™ 9800i Scanner
ScaleSentry / Scale Service Button
The ScaleSentry / Scale Service Button (item #3 in
) is used for multiple functions as
Table 18. ScaleSentry / Scale Service Button Functions
PRESS
DURATION
FUNCTION
COMMENT
Momentary
Override
If a ScaleSentry event is occurring, this will override the scale sentry
event. If no ScaleSentry event is occurring, this will activate the man-
ual tare function of the scale.
4 Seconds
Scale Diagnostics
Mode
a
a.
Diagnostics Mode is meant for use by trained systems support personnel. Users should
not need to initiate this function under normal circumstances.
This mode allows system support personnel to troubleshoot problems
with the scale. Momentarily press the Scale Zero Button or cycle power
to exit Scale Diagnostics Mode. See the topic,
in the
section for more details.
8 Seconds
Resets Scanner
Only system support personnel should perform a reset.
Momentary while
in Scale
Diagnostics Mode
Resets Scanner
A scanner reset can also be initiated by a momentary press of this but-
ton while in Scale Diagnostics Mode.
DECOUPLED MODE
Deactivation
Indicated
Deactivation (Tri-color) LED
flashes Red.
EAS Beep OFF
An EAS tag has been
successfully deacti-
vated.
HYBRID MODE
Deactivation
Indicated
Deactivation (Tri-color) LED
flashes Red, then Orange, then
returns to Green.
High frequency beep
An EAS tag has been
successfully deacti-
vated.
a.
Additionally, the FRU LED (Health & Status Indicator located in the bottom of the
optic cavity — visible through the horizontal scan window) blinks the number ‘9’. If
EAS deactivation fails to initiate, a low, error tone will be sounded, and the FRU LED
will display the error code ‘9’ steadily (without flashing).
b.
Ticking sound will stop upon one of the following: 1) Manual EAS Deactivation Push
Button is pressed and released again, 2) EAS timer runs out, or 3) Following a suc-
cessful EAS tag deactivation.
Table 17. EAS Indications
Summary of Contents for Magellan 9800i
Page 1: ...MagellanTM 9800i Product Reference Guide...
Page 62: ...Site Preparation and Installation 50 Magellan 9800i Scanner NOTES...
Page 102: ...Calibration Procedures 90 Magellan 9800i Scanner NOTES...
Page 112: ...Programming 100 Magellan 9800i Scanner NOTES...
Page 158: ...Enter Exit Programming Mode 146 Magellan 9800i Scanner NOTES...
Page 174: ...EAS Features 162 Magellan 9800i Scanner NOTES...
Page 378: ...Enter Exit Programming Mode 366 Magellan 9800i Scanner NOTES...
Page 400: ...2D Symbology Programming 388 Magellan 9800i Scanner NOTES...
Page 414: ...402 Magellan 9800i Scanner NOTES...
Page 424: ...412 Magellan 9800i Scanner NOTES...
Page 438: ...426 Magellan 9800i Scanner NOTES...
Page 450: ...438 Magellan 9800i Scanner NOTES...