Increasing Load Test (Phase 2 Dual Interval ONLY)
After completing the Shift Test, you must complete the Increasing Load Test using 4, 5 and 6
kilograms of weight.
NOTE
The upper limit of the scale is configurable according to POS interface type and may not
necessarily be set at 15 kilograms, which is the standard setting. For this test, continue to
place weights in 1 kilogram increments only to the upper weight limit set for your scale.
DUAL INTERVAL
1. Place 4 kilograms in the center of the weighing
surface and check that the Remote
Display reads between 3.998 kg and 4.002 kg.
2. Place an additional 1 kilogram in the center of
the weighing surface and check that the display
reads between 4.998 kg and 5.002 kg.
3. Place an additional 1 kilogram in the center of
the weighing surface and check that the display
reads between 5.998 kg and 6.005 kg.
4. Increase the weight on the center of the weigh-
ing surface to 7.50 kg and check that the display
reads between 7.495 and 7.505 kg.
5. Remove the weights and verify that the display
reads 0.000 kg. You have completed the
Increasing-Load Test.
Shift Test — Metric (5 Kilograms)
The Shift Test checks to ensure that items placed anywhere on the weighing surface of the
scanner/scale are weighed properly. Refer to
when performing this test.
SINGLE INTERVAL
DUAL INTERVAL
1. Place and remove in succession, a 5.0 kilogram
load on the center of each of the four quadrants
(2, 3, 4, and 5 in
) and in the center (1)
of the scanner/scale’s weighing platform. Ver-
ify that the display shows a reading of between
4.995 and 5.005 kg for each quadrant/center
test and that the display returns to 0.000
between each load.
1. Place and remove, in succession, a 5.0 kilogram
load on the center of each of the four quadrants:
2, 3, 4, and 5, and in the center (1) of the scan-
ner/scale’s weighing platform (see
Verify that the Remote Display shows a reading
of between 4.998 and 5.002 kg for each quad-
rant/center test. Check that the display returns to
0.000 between each load.
2.
A
fter verifying the accuracy of each quadrant
and the center of the weighing surface, remove
all weight from the scale. This completes the
Shift Test — Metric (5 Kilograms).
2. A
fter verifying the accuracy of each quadrant and
the center of the weighing surface, remove all
weight from the scale. This completes the Shift
Test — Metric (5 Kilograms).
Summary of Contents for Magellan 9800i
Page 1: ...MagellanTM 9800i Product Reference Guide...
Page 62: ...Site Preparation and Installation 50 Magellan 9800i Scanner NOTES...
Page 102: ...Calibration Procedures 90 Magellan 9800i Scanner NOTES...
Page 112: ...Programming 100 Magellan 9800i Scanner NOTES...
Page 158: ...Enter Exit Programming Mode 146 Magellan 9800i Scanner NOTES...
Page 174: ...EAS Features 162 Magellan 9800i Scanner NOTES...
Page 378: ...Enter Exit Programming Mode 366 Magellan 9800i Scanner NOTES...
Page 400: ...2D Symbology Programming 388 Magellan 9800i Scanner NOTES...
Page 414: ...402 Magellan 9800i Scanner NOTES...
Page 424: ...412 Magellan 9800i Scanner NOTES...
Page 438: ...426 Magellan 9800i Scanner NOTES...
Page 450: ...438 Magellan 9800i Scanner NOTES...