background image

 

 

MATRIX-1000™ QUICK GUIDE

 

2

 

 

 

 
 
 

 

 

 

Figure A 

 

Reading Window 

Auxiliary Interface 

Main Tx LED 

Good Read LED 

Main/Auxiliary Interface

5

6

7

External Trigger LED

Power On LED 

 

 
 

 

NOTE 

For further details on product installation, see the complete Installation Manual available on the 
CD included with this product. 

 
 
 

Compliance: 
 

This product is intended to be installed by Qualified Personnel only. 

-  This product is intended to be connected to a UL Listed 

Computer which supplies power directly to the reader or a 
UL Listed Direct Plug-in Power Unit marked LPS or 
“Class 2”, rated 10 to 30 V, minimum 1 A. 

-  In order to meet the EMC requirements: 

• 

connect reader chassis to the plant earth ground by 
means of a flat copper braid shorter than 100 mm; 

• 

connect the main interface cable shield to pin 1 of the 
reader 25-pin connector; 

• 

use two clip-on ferrite sleeves (type Stewart 28A2029-
0A0) on the main interface cable near the reader 25-
pin connector; 

 

 
 

 

TO EN 60825-1:2001 

 

 
 

Model Description: 

 

 

MATRIX - 10X1 

Optics

2 = High Density (HD) 

3 = Standard Density (STD)

4 = Low Density (LD) 

5 = Medium Range (MR) 

 

 
 
 

4

5

3

2

Summary of Contents for Matrix-1021 HD

Page 1: ...Matrix 1000 QUICK REFERENCE GUIDE...

Page 2: ...sted Computer which supplies power directly to the reader or a UL Listed Direct Plug in Power Unit marked LPS or Class 2 rated 10 to 30 V minimum 1 A In order to meet the EMC requirements connect read...

Page 3: ...28 Code 93 Code 39 Standard and Full ASCII Interleaved 2 of 5 EAN 8 13 UPC A E including Addon 2 and Addon 5 2 D Data Matrix ECC 200 QR Code POSTAL Australia Post PLANET Royal Mail 4 State Customer PO...

Page 4: ...nt conditions Test chart provided with the reader Still code at the center of the FOV Code symbology Data Matrix ECC 200 Code resolution Typ 2D Code Resolution Tilt angle 45 Pitch angle 15 Decode mode...

Page 5: ...cted 11 12 NC Not connected 16 OUT 3 Configurable digital output 3 positive pin 17 OUT 3 Configurable digital output 3 negative pin 18 EXT_TRIG A External trigger polarity insensitive 19 EXT_TRIG B Ex...

Page 6: ...8 CTS 5 CTS How To Build A Simple Interface Test Cable The following wiring diagram shows a simple test cable including power external push button trigger and PC RS232 COM port connections 25 pin D su...

Page 7: ...X 100 C BOX 100 Terminal Block Connectors Power 1 3 5 VS 2 4 6 GND 7 8 EARTH GROUND 20 40 Reserved Inputs 27 EXT TRIG A polarity insensitive 28 EXT TRIG B polarity insensitive 29 30 NC 31 33 NC 32 34...

Page 8: ...T 30 Vdc Max Input NPN command using external power USER INTERFACE VS MATRIX A B GND V VCC GND 9 OUT 25 Input NPN command using Matrix 1000 power The electrical features of the input are INPUT V AB Mi...

Page 9: ...inch M4 x 5 n 4 18 1 0 71 4 0 16 73 2 87 57 2 24 28 1 1 11 57 2 24 121 4 76 57 2 24 M4 x 5 n 4 57 2 24 Overall Dimensions 73 2 87 4 2 0 17 15 0 59 37 1 46 4 2 0 17 95 3 74 47 5 1 87 8 2 0 3 2 47 5 1 8...

Page 10: ...0 C BOX 100 C BOX 100 C BOX 100 Power Host e e e d d d c c Multidrop Network Main Interface d Auxiliary Interface Local Echo e External Trigger 0 31 1 Matrix 1000 c Auxiliary Interface Local Echo d Ex...

Page 11: ...to electromagnetic compatibility and product safety Bas e sur la l gislation des Etates membres relative la compatibilit lectromagn tique et la s curit des produits ber die Ann herung der Gesetze der...