HOST MODE PROGRAMMING
6
3
Example:
Reading Phase Timeout
parameter
Type: 0
Label:
Reading Phase Timeout
Range: 35,
60000
Default: 1000
Enumerative (Type = 1)
Item List
List of the values allowed for the parameter.
Selection
Maximum number of values selectable at the same time (normally equal to 1).
Default
Default entry (i.e. 0 = first entry of the list, 1 = second entry of the list).
Example:
Operating Mode
parameter.
Type: 1
Label: Operating
Mode
Item List
One Shot
,
Continuous
,
Phase Mode
Selection: 1
Default:
0 (Entry 0
One Shot)
String (Type = 2)
Length
Minimum and maximum number of characters allowed for this parameter.
Default
Default value (String).
Example:
Link Failure String
parameter.
Type: 2
Label: Link
Failure
String
Length: 0,
32
Default: Empty
string