MATRIX 210™ PARAMETERS LIST
23
4
PARAMETER TYPE
SEL
STRING
DATA
Reading Phase OFF
4
11
ESC A D
1 = Ext. Trig. Leading Edge
2 = Ext. Trig. Trailing Edge
4 = Main Port String
8 = Auxiliary Port String
16 = Input 2 Leading Edge
32 = Input 2 Trailing Edge
64 = Timeout
128 = Complete Read
256 = Ethernet String
512 = Ethernet IP Input Leading Edge
1024 = Ethernet IP Input Trailing Edge
2048 = Fieldbus String
4096 = Fieldbus Input Leading Edge
8192 = Fieldbus Input Trailing Edge
16834 = ID-NET String
Reading Phase Timeout
(ms)
0
ESC A E
Range: 17 to 60000
Timeout Counting From 1
1
ESC A N
0 = Reading Phase ON
1 = Reading Phase OFF
Acquisition Trigger (One
Shot)
4
7
ESC A F
1 = Ext. Trig. Leading Edge
2 = Ext. Trig. Trailing Edge
4 = Main Port String
8 = Auxiliary Port String
16 = Ethernet String
32 = Ethernet IP Input Leading Edge
64 = Ethernet IP Input Trailing Edge
128 = Fieldbus String
256 = Fieldbus Input Leading Edge
512 = Fieldbus Input Trailing Edge
1024 = ID-NET String
First Acquisition Setting
Used
1
1
ESC A H
0 = First Enabled
1 = Last Successful
Number of Image Slots 0
ESC A L
Range: 1 to 300
Code Filter Depth
0
ESC A I
Range: 0 to 5
Code Filter Selection
1
1
ESC A N
0 = Acquisition Counter Threshold
1 = Timeout Threshold
Good Read Threshold
0
ESC A J
Range: 0 to 100000
No Read Threshold
0
ESC A K
Range: 0 to 100000
Timeout Threshold
(sec)
0
ESC A O
Range: 0 to 300
(0 = Disabled)
ACQUISITION TRIGGER DELAY (DEPTH: n = 1 to 10)
Status
#n
1
1
ESC
n
#n
0 = Disabled
1 = Enabled
Delay Time
#n
(x100
s)
0 ESC
o
#n
Range: 0 to 100000
NOTE
Special characters <
FE
H
> and <
FD
H
> must be added after
#n
in the
programming string to indicate parameter
Depth > 9
. Refer to paragraph 3.2
for further details.