HOST MODE PROGRAMMING
24
4
USB CONNECTOR MODELS
PARAMETER TYPE
SEL
STRING
DATA
OPERATING MODES
Operating Mode
1
1
ESC A A
0 = One Shot
1 = Continuous
2 = Phase Mode
Reading Phase ON
4
1
ESC A B
1 = Main Port String
Acquisition Trigger
(Phase Mode)
4
ESC A C
1 = Continuous
2 = Multi-Delay
4 = Periodic
8 = Main Port String
Acquisition Trigger
Period (ms)
(Phase Mode)
0
ESC A G
Range: 17 to 60000
Reading Phase OFF
4
1
ESC A D
1 = Main Port String
2 = Timeout
4 = Complete Read
Reading Phase Timeout
(ms)
0
ESC A E
Range: 17 to 60000
Timeout Counting From 1
1
ESC A N
0 = Reading Phase ON
1 = Reading Phase OFF
Acquisition Trigger (One
Shot)
4
1
ESC A F
1 = Main Port String
First Acquisition Setting
Used
1
1
ESC A H
0 = First Enabled
1 = Last Successful
Image Acquisition
Buffer Size
0
ESC A L
Range: 1 to 300
Code Filter Depth
0
ESC A I
Range: 0 to 5
Code Filter Selection
1
1
ESC A W
0 = Acquisition Counter Threshold
1 = Timeout Threshold
Good Read Threshold
0
ESC A J
Range: 0 to 100000
No Read Threshold
0
ESC A K
Range: 0 to 100000
Timeout Threshold
(sec)
0
ESC A O
Range: 0 to 300
(0 = Disabled)
ACQUISITION TRIGGER DELAY (DEPTH: n = 1 to 10)
Status
#n
1
1
ESC
n
#n
0 = Disabled
1 = Enabled
Delay Time
#n
(x100
s)
0 ESC
o
#n
Range: 0 to 100000
NOTE
Special characters <
FE
H
> and <
FD
H
> must be added after
#n
in the
programming string to indicate parameter
Depth > 9
. Refer to paragraph 3.2
for further details.
Summary of Contents for Matrix 210