MATRIX 210™ PARAMETERS LIST
35
4
4.6 READING SYSTEM LAYOUT
25 PIN CONNECTOR MODELS
ETHERNET MODELS
PARAMETER TYPE
SEL
STRING
DATA
READING SYSTEM LAYOUT
Device Network Setting
1
1
ESC A R
0 = Alone Or ID-NET
1 = Master RS232 (Type A)
2 = Slave RS232 (Type A)
3 = Master RS232 (Type M)
4 = Slave RS232 (Type M)
Number of Slaves (Type
A or M)
0
ESC A S
Range: 1 to 9
Link Failure String
2
ESC A T
Length: 0 to 32
Link Failure Timeout
(ms)
0
ESC A U
Range: 10 to 10000
DEVICE NETWORK SETTING
Topology Role
1
1
ESC A a
0 = Other
1 = Master (Synchronized)
2 = Slave (Synchronized)
3 = Master (Multidata)
4 = Slave (Multidata)
Slave Address
0
ESC A b
Range: 1 to 31
Network Baud Rate
(bps)
1
1
ESC A c
0 = 19200
1 = 38400
2 = 57600
3 = 125 Kb
4 = 250 Kb
5 = 500 Kb
6 = 1 Mb
Link Failure String
2
ESC A d
Length: 0 to 32
Link Failure Timeout
(ms)
0
ESC A e
Range: 10 to 10000
Header String
(Slave Multidata)
2
ESC A f
Length: 0 to 128
Terminator String
(Slave Multidata)
2
ESC A g
Length: 0 to 128
Address TX
(Master Multidata)
1
1
ESC A h
0 = Disabled
1 = Enabled
Address Header String
(Master Multidata)
2
ESC A i
Length: 0 to 32
Address Separator
String
(Master Multidata)
2
ESC A l
Length: 0 to 32
EXPECTED SLAVE DEVICE (DEPTH: n = 1 to 31)
Device Status #n
1
1
ESC J #n
0 = Disabled
1 = Enabled
Device Description #n
2
ESC K #n
Length: 0 to 16
NOTE
Special characters <
FE
H
> and <
FD
H
> must be added after
#n
in the
programming string to indicate parameter
Depth > 9
. Refer to paragraph 3.2
for further details.