HOST MODE PROGRAMMING
38
4
PARAMETER TYPE
SEL
STRING
DATA
IP Addressing
1
1
ESC S y
0 = Static Assignment
1 = DHCP
2 = Remote Assignment
IP Address
(Static Addressing)
2
ESC S z
Length: 1 to 15
Subnet Mask (Static
Addressing)
2
ESC S !
Length: 1 to 15
Gateway Address
(Static Addressing)
2
ESC S #
Length: 1 to 15
Station Name
2
ESC S $
Length: 1 to 32
MODBUS TCP
Master Input Area Size
0
ESC S %
Range: 8 to 144
Master Output Area
Size
0
ESC S &
Range: 8 to 144
Data Flow Control
1
1
ESC S (
0 = Disabled
1 = DAD Driver
Data Consistency
1
1
ESC S )
0 = Disabled
1 = Enabled
IP Addressing
1
1
ESC S *
0 = Static Assignment
1 = DHCP
2 = Remote Assignment
IP Address
(Static Addressing)
2
ESC S +
Length: 1 to 15
Subnet Mask (Static
Addressing)
2
ESC S /
Length: 1 to 15
Gateway Address
(Static Addressing)
2
ESC S :
Length: 1 to 15
Process Active Timeout
(ms)
0
ESC S -
Range: 0 to 65535
Connection Timeout
(sec)
0
ESC S {
Range: 0 to 65535
DIGITAL I/O CONDITIONING
Phase Echo
1
1
ESC S S
0 = Disabled
1 = Enabled
External Trigger Echo
1
1
ESC S T
0 = Disabled
1 = Enabled
Input 2 Echo
1
1
ESC S U
0 = Disabled
1 = Enabled
Output 1
1
1
ESC S V
0 = Disabled
1 = Enabled
Output 2
1
1
ESC S W
0 = Disabled
1 = Enabled