MATRIX 210™ PARAMETERS LIST
63
4
4.14 LEDS AND KEYPAD
PARAMETER TYPE
SEL
STRING
DATA
KEYPAD
Status
1
1
ESC N A
0 = Disabled
1 = Enabled
Button Function 1
(a) only for ETHERNET
MODELS
1
1
ESC N G
0 = Disabled
1 = Autolearning
2 = Calibration Only
3 = Code Setting Only
4 = Positioning
5 = Restore Default
6 = Test Mode
7 = Locate
8 = Store Match Code
9 = Enable DHCP (a)
Button Function 2
(a) only for ETHERNET
MODELS
1
1
ESC N H
0 = Disabled
1 = Autolearning
2 = Calibration Only
3 = Code Setting Only
4 = Positioning
5 = Restore Default
6 = Test Mode
7 = Locate
8 = Store Match Code
9 = Enable DHCP (a)
Button Function 3
(a) only for ETHERNET
MODELS
1
1
ESC N I
0 = Disabled
1 = Autolearning
2 = Calibration Only
3 = Code Setting Only
4 = Positioning
5 = Restore Default
6 = Test Mode
7 = Locate
8 = Store Match Code
9 = Enable DHCP (a)
Button Function 4
(a) only for ETHERNET
MODELS
1
1
ESC N U
0 = Disabled
1 = Autolearning
2 = Calibration Only
3 = Code Setting Only
4 = Positioning
5 = Restore Default
6 = Test Mode
7 = Locate
8 = Store Match Code
9 = Enable DHCP (a)
LEDS
Green Spot Activation
Events (Match Code
disabled)
3
4
ESC N W
0 = None
1 = Decoding
2 = Complete Read
4 = Partial Read
8 = No Read
16 = Multiple Read