HOST MODE PROGRAMMING
64
4
PARAMETER TYPE
SEL
STRING
DATA
Green Spot Activation
Events (Match Code
enabled)
3
4
ESC N X
0 = None
1 = Decoding
2 = Right Code
4 = Wrong Code
8 = No Read
16 = Multiple Read
Green Spot
Deactivation Timeout
(sec)
O
ESC N Y
Range: 1 to 300
(0 = Disabled)
COM LED Function
1
1
ESC N C
0 = Main COM Port RX
1 = Main COM Port TX
2 = Network Present
3 = Network RX
4 = Network TX
Aiming System Status
1
1
ESC N Z
0 = Disabled
1 = Enabled
LEDs Deactivation
Timeout (sec)
0
ESC N V
Range: 0 to 300
Partial Read Treated As 1
1
ESC N a
0 = No Read
1 = Complete Read
Multiple Read Treated
As
1
1
ESC N f
0 = No Read
1 = Complete Read
BEEPER
Status
1
1
ESC N T
0 = Disabled
1 = Enabled
Activation Events
(Match Code disabled)
3
4
ESC N D
0 = None
1 = Decoding
2 = Complete Read
4 = Partial Read
8 = No Read
16 = Multiple Read
Activation Events
(Match Code enabled)
3
4
ESC N E
0 = None
1 = Decoding
2 = Right Code
4 = Wrong Code
8 = No Read
16 = Multiple Read
Deactivation Timeout
(ms)
0
ESC N F
Range: 1 to 1500
TEST MODE SETUP
Image Acquisition
Setting
0
ESC N b
Range: 1 to 10
Number Of Samples
0
ESC N c
Range: 5 to 1000
Test Mode Data TX
3
3
ESC N d
0 = None
1 = Auxiliary Port
2 = Main Port
4 = ID-NET
8 = Host Interface Port
Test Mode Exit Timeout
(sec)
0
ESC N e
Range: 1 to 300
(0 = Disabled)
Summary of Contents for Matrix 210