PASS-THROUGH
PRODUCT REFERENCE GUIDE
101
PASS-THROUGH
The pass-through layout allows each device
working Alone
, to collect data from one or
more pass-through input channels and send this data plus its own on one or more dif-
ferent output channels.
In this way independent devices can be connected together in combinations to create
multi device networks. Many devices reading independently can send their messages
through a common output channel which instead of being directed at a Host can be col-
lected by another device on its pass-through input channel and sent to a Host on a dif-
ferent output channel.
Host
CAB-DS
xx-S
Phase
CAB-ET
H-X-
M0
x
Ethernet TCP/IP Server 1
Ethernet TCP/IP Server 2
Main Serial Interface (RS232 or RS422 Full-Duplex)
Auxiliary Serial Interface (RS232)
Pass-through Input Channel
Output Channel
Alone
Alone
Alone
CBX
Switch
Power
Mode
Continuous
Mode
External
Trigger
Figure 79 - Pass-Through Layout
In a Pass-through layout each device supports multiple pass-through configurations to
accept input from different devices on different channels (i.e. middle reader above). How-
ever, readers are not required to have a pass-through configuration if they don’t need to
receive data from an input channel (i.e. right reader above). The overall data collection
device always has at least one pass-through configuration to collect the input data from
the other devices and send it to the Host (i.e. left reader above).
All devices always support multiple output channels (i.e. for data monitoring).
In a Pass-through layout each device can have a different operating mode: Continuous,
One Shot, Phase Mode, etc.
Summary of Contents for Matrix 220
Page 1: ...Matrix 220 PRODUCT REFERENCE GUIDE Image Based Reader...
Page 18: ...GENERAL VIEW xviii MATRIX 220...
Page 102: ...ELECTRICAL CONNECTIONS 84 MATRIX 220 Figure 57 NPN External Trigger Using Matrix 220 Power...
Page 163: ...PASS THROUGH CONFIGURATIONS PRODUCT REFERENCE GUIDE 145...
Page 171: ...INTERNAL NETWORK CONFIGURATIONS PRODUCT REFERENCE GUIDE 153...
Page 173: ...INTERNAL NETWORK CONFIGURATIONS PRODUCT REFERENCE GUIDE 155 Open the cloned application job...
Page 211: ......