SOFTWARE CONFIGURATION
172
MATRIX 220
Diagnostic Alarms
Diagnostic error messages are sent to the BM150 display as numeric Alarm Codes, (even
if Failure Messages are selected for data transmission the numeric Alarm Code is sent to
the display).
X = numeric Alarm Code (see below for the list of Alarm Codes)
R = Device Network Type – MUL=Multidata, SYN=Synchronized, ALN=Alone
N = Device Network Setting – M00=ID-NET Network Master, Sxx= ID-NET Network Slave
address, Null string= Alone (no network)
Alarm Code
Description
1
Slave No Reply
64
Slave Address Duplication
171
Protocol Index Failure
185
Backup Memory Communication Failure
187
Wrong Rotary Switch Selection
189
Fieldbus Communication Failure
191
Fieldbus Type Mismatch
193
Fieldbus Configuration Error
195
Fieldbus DHCP Problem
201
No XRF Slave(s) Detected
Slave Node Alarms (Master only)
X = slave node number (1-31)
R = Device Network Type – MUL=Multidata, SYN=Synchronized