BM150 DISPLAY MODULE CONFIGURATION AND MESSAGES
PRODUCT REFERENCE GUIDE
175
BM150 Backup and Restore Procedure
The Backup and Restore functions are valid for any application layout type (point-to-
point, network, etc.) using CBX500 connection boxes through the BM100 Backup mod-
ule (required accessory for BM150 installation).
The Backup and Restore functions are managed through the BM150 display and keypad
and therefore are disabled at the BM100 Backup/Restore button.
If it ever becomes necessary to replace the reading device it can be quickly configured
through the restore procedure.
BM150 provides complete backup and restore functions (Configuration and Environ-
mental parameters) with the following difference:
For Single Readers or individual ID-NET Slaves:
•
Backup and Restore functions provide parameter storage including all configura-
tion jobs present on the reader.
For Master Readers in ID-NET Master/Slave networks:
•
Backup and Restore functions provide parameter storage of only the Startup Con-
figuration for the Master and all Slaves present in the network.
The Slaves must always be configured with the same network baudrate as the Master
for correct functioning including performing Backup and Restore procedures.
Backup and Restore functions cannot be interrupted once started.
To perform
Backup
1. Make sure the Write Protection switch on the BM100 is unlocked.
2. Select the
Backup
item from the Extended menu and press the Enter key.
3. When the procedure is complete a message appears on the display showing the
results (
Backup OK 1 File Saved
or an error message).
4. Set the Write Protection switch to locked.
To perform
Restore
1. Select the
Restore
item from the Extended menu and press the Enter key.
2. When the procedure is complete a message appears on the display showing the
results (
Restore OK 1 File Restored
or an error message).
CAUTION
For Master/Slave networks any other configurations (jobs) stored in the
device memory will not be backed up. Therefore upon a restore, all jobs
other than the startup configuration will be overwritten (erased). It is
strongly recommended to save all configurations to backup files.
Summary of Contents for Matrix 220
Page 1: ...Matrix 220 PRODUCT REFERENCE GUIDE Image Based Reader...
Page 18: ...GENERAL VIEW xviii MATRIX 220...
Page 102: ...ELECTRICAL CONNECTIONS 84 MATRIX 220 Figure 57 NPN External Trigger Using Matrix 220 Power...
Page 163: ...PASS THROUGH CONFIGURATIONS PRODUCT REFERENCE GUIDE 145...
Page 171: ...INTERNAL NETWORK CONFIGURATIONS PRODUCT REFERENCE GUIDE 153...
Page 173: ...INTERNAL NETWORK CONFIGURATIONS PRODUCT REFERENCE GUIDE 155 Open the cloned application job...
Page 211: ......