STEP 6 - DEVICE CONFIGURATION
PRODUCT REFERENCE GUIDE
21
10. Click on the Data Matrix ECC 200 symbology under the Image Settings branch
(enabled by default). If this symbology is among those in your application it will be
shown in the image display with its code symbology name and a small green box
around it indicating it is decoded.
NOTE
11. Add your application specific codes to the Code Settings by selecting them from
the icons over the Configuration Parameters tree area. If the Data Matrix symbol-
ogy is not used, then delete it from the Code Settings with the Delete icon.
If you don’t know the code type, you can use the Code Autolearn feature by click-
ing on the Code Autolearn icon.
1
See the DL.CODE User’s Manual for details.
12. For each code symbology set the relative parameters according to your applica-
tion.
The large green box for each symbol indicates the code localization area
which by default is equal to the maximum FoV. It can be resized and
moved by dragging its borders with the mouse. The code must be found
within this area in order to be decoded.
1.
The Code Autolearn procedure will not recognize the following symbologies: Pharmacode, MSI,
Standard 2 of 5, Matrix 2 of 5.
Summary of Contents for Matrix 220
Page 1: ...Matrix 220 PRODUCT REFERENCE GUIDE Image Based Reader...
Page 18: ...GENERAL VIEW xviii MATRIX 220...
Page 102: ...ELECTRICAL CONNECTIONS 84 MATRIX 220 Figure 57 NPN External Trigger Using Matrix 220 Power...
Page 163: ...PASS THROUGH CONFIGURATIONS PRODUCT REFERENCE GUIDE 145...
Page 171: ...INTERNAL NETWORK CONFIGURATIONS PRODUCT REFERENCE GUIDE 153...
Page 173: ...INTERNAL NETWORK CONFIGURATIONS PRODUCT REFERENCE GUIDE 155 Open the cloned application job...
Page 211: ......